EXTender
TM
7000 Installation Guide
Page 36
The following menu appears:
Figure 3-14: T1/PRI Port (WAN3) Parameters
2.
Set the
Clock Source
parameter to T1PRI_Port1.
3.
Set the
Enabled
parameter to Yes.
4.
Set to Port 1 if the network is providing timing, or Port 2 to use the EXTender 7000 for the timing source.
Note: Point-to -Point T1’s DO NOT provide timing.
5.
Set the
Mode
parameter to PRI.
6.
The
Switch Type
,
Line Code
and
Framing
parameters to be provided by the Telco.
7.
The PBXgateway II uses the
Dialback DN
parameter to connect to the EXTender 7000. Enter a phone
number of the PRI line that is connected to the EXTender 7000.
8.
Set the
Line Code
and
Framing
parameters with values provided by the Telco company (CO).
9.
Select a value for the
Line Build Out
parameter to attenuate the signal before it leaves the extender.
Use a value recommended by the Telco company (CO).
Channel Setup - PRI
Assigning DS0 Channels
1.
Use the arrow keys to access the DS0_Default Channel Setup menu, as shown below:
MI Path
Configuration->WAN->T1/PRI_Port(WAN3)->T1/PRI_Port_1-> Channel Setup-
>DS0_Default
Figure 3-15: Assigning DS0 Channels