Oper
ation
Fusion Outlet
4 - 2
Operation - Fusion Outlet
Hornet™ XL
¡PELIGRO!
Prepare Heater
This heater is not explosion proof. Operation of
heater in an explosive atmosphere without necessary
safety precautions will result in serious injury or
death.
When operating in an explosive atmosphere, the heater
should be brought up to temperature in a safe environment,
then unplugged before entering the explosive atmosphere for
fusion.
1)
Ensure the heater is cool. Install fusion outlet heater
adapters.
NOTICE:
The heater should never be used without fusion
heater adapters installed. Refer to the
installation procedure.
2)
Place heater in insulated heater bag.
3)
Plug heater into a proper power source. Refer to
Heater Information Label for power information.
Adjusting Heater Temperature:
4)
Turn knob to desired temperature. Allow heater to reach
temperature. Measure the heater surface temperature
with a pyrometer. Any variance must be corrected to
the pyrometer reading.
Loosen set screw in the knob. Turn knob to point to the
temperature of the pyrometer reading. Tighten set screw
in the knob.
Turn knob to desired temperature. Allow heater to
stabilize at the new temperature (5 to 10 minutes) after
adjusting.
The thermometer on the heater body indicates internal
temperature and should be used as a reference only.
The heater has a green indicator light which will flash on and
off. This indicates that the controller is operating normally. If
the green indicator is not flashing then the controller may not
be operating properly. If this occurs, disconnect power and
have the heater repaired by an McElroy Authorized Service
Center.
The heater has a red indicator light on the handle at the
bottom of the temperature scale. When the heater is plugged
in and preheating the red light glows steadily until the set
temperature is reached. The red light then goes off and on as
the heater maintains temperature.
If the heater is not operating properly, the control will attempt
to turn the heater off and the red indicator light will flash
rapidly. If this occurs, disconnect the power and take it to a
McElroy Authorized Service Center for repair.
5)
Allow heater to warm-up to operating temperature.