![McElroy Hornet XL ASW31401 Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/mcelroy/hornet-xl-asw31401/hornet-xl-asw31401_operators-manual_1754753024.webp)
Oper
ation - Sock
et
Fuse to Outlet
5 - 1
Operation - Socket Fuse to Outlet
Hornet™ XL
OPERATION - SOCKET FUSE TO OUTLET
After creating a fusion outlet on a main pipe, you can use
the Hornet™ XL to fuse a pipe to the fusion outlet. A 63mm to
125mm outlet requires a socket fusion to be performed. Leave
the machine attached in the same position after making the
fusion outlet. The jaw inserts and socket fusion heater adapters
are not included and will need to be obtained separately.
Prepare Pipe End
1)
Cut off damaged or oval ends of pipe squarely with a
pipe cutter.
2)
Remove shavings and burrs inside pipe end.
Prepare Heater
This heater is not explosion proof. Operation of
heater in an explosive atmosphere without necessary
safety precautions will result in serious injury or
death.
When operating in an explosive atmosphere, the heater
should be brought up to temperature in a safe environment,
then unplugged before entering the explosive atmosphere for
fusion.
1)
Ensure the heater is cool. Install socket fusion heater
adapters (not included) for 63mm to 125mm outlets.
Refer to
“Changing Heater Plates/Adapters”
in the
Maintenance section for information about heater
plates and adapters.
NOTICE:
The heater should never be used without fusion
heater adapters installed.
2)
Place heater in insulated heater bag.
3)
Plug heater into a proper power source. Refer to
Heater Information Label for power information.
Adjusting Heater Temperature:
4)
Turn knob to desired temperature. Allow heater to reach
temperature. Measure the heater surface temperature
with a pyrometer. Any variance must be corrected to
the pyrometer reading.
Loosen set screw in the knob. Turn knob to point to the
temperature of the pyrometer reading. Tighten set screw
in the knob.
Turn knob to desired temperature. Allow heater to
stabilize at the new temperature (5 to 10 minutes) after
adjusting.
The thermometer on the heater body indicates internal
temperature and should be used as a reference only.
The heater has a green indicator light which will flash on and
off. This indicates that the controller is operating normally. If
the green indicator is not flashing then the controller may not
be operating properly. If this occurs, disconnect power and
have the heater repaired by an McElroy Authorized Service
Center.
The heater has a red indicator light on the handle at the
bottom of the temperature scale. When the heater is plugged
in and preheating the red light glows steadily until the set
temperature is reached. The red light then goes off and on as
the heater maintains temperature.
¡PELIGRO!
CD00999-2-21-18
CD02479-03-15-19
CD02152-2-21-18