23
Note
Immediately after issuing a Baud Rate Select command, the Host
system serial port must also change to the matching baud rate.
< > Control keys.
Syntax: 1 (9200) | 5(7600)
Description:
The Baud Rate Select command sets the units serial port to 19.2K or 57.6K baud.
The unit defaults to 19.2K baud at power-up.
Executing a Remote Trace on high volumes of bus traffic at 19.2K baud may
cause loss of data on buffer overflows. Buffer overflows are marked in the data
stream with the “???” string.
When executing a Remote Trace at 57.6K baud, the HOST system may lose data
on character overwrites. Character overwrite detection is a function of your
terminal emulation program.
Example: 5 <Enter> - 57.6K baud selected.
1 <Enter> - 19.2K baud selected.
Baud Rate Select