![MBM FEMD110 Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/mbm/femd110/femd110_installation-use-and-maintenance-instructions_1752675018.webp)
- 18 -
GB
4.7
SPECIAL OPERATIONS
4.7.1
FILLING THE STEAM GENERATOR
The steam generator is filled as soon as a mode or a baking program is selected.
The water level in the steam generator is controlled by a float.
4.7.2
LIGHTING OF THE BAKING AREA
- Lighting enabled when the door is closed
- Lighting enabled when the door is open + start enabled (except in case of delayed start)
- Lighting disabled when the door is open + stop enabled
4.8
ALARMS AND MESSAGES
Some operating errors are managed electronically and displayed.
Such errors are numbered and if one of these occurs when the appliance is working, the display shows the relevant number
0
Component overheating
1
Baking area overheating
2
Temperature probe of the faulty baking area
3
Faulty core probes
4
Faulty turbines
5
Heating elimination (only electrical)
6
(Electrical) counter overheating
7
Faulty convection burner
Before proceeding with any baking mode, you must correct the displayed errors; otherwise the error shall remain displayed.
4.8.1
DESCRIPTION OF ALARMS
Alarm 0 Component overheating
A thermal probe on the board checks the temperature of the components, if it exceeds 65°C, the heating is stopped in all
baking modes.
Alarm 1 Baking area overheating
The safety thermostat in the baking area opens up as the temperature exceeds 350°C. If convection heating is on, it is cut off.
If the turbine is working during the alarm, it keeps working.
Alarm 2 Temperature probe of the faulty baking area
If this probe breaks down or is stopped, the temperature is no longer displayed.
The oven cannot work in any mode.
Alarm 3 Faulty core probes
If a probe breaks down or is stopped, the temperature is no longer displayed; the core probe mode can no longer be used.
The oven works in convection and steam modes.