![MBM FEMD110 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/mbm/femd110/femd110_installation-use-and-maintenance-instructions_1752675015.webp)
- 15 -
GB
4.4.3
CORE PROBE
Enable the relevant key and the temperature value of the roasting-meter shall replace that of the
baking time. (default setting 60°C)
Choose a roasting-meter cooking temperature with the value setting button.
Enable the START/STOP key
to start the baking (after starting, you can display the baking
time left by enabling the following key
).
The baking ends when the temperature set for the core probe is reached. The buzzer is enabled if
the temperature set for the roasting-meter is greater than 70°C.
A temperature maintenance phase in the combined mode is enabled if the roasting-meter tempe-
rature falls under 70°C:
In combined mode at 160°C:
- the relief valve is closed
· the fan turns at low speed
(These parameters can be modified)
The opening of the door stops this phase of temperature maintenance that cannot be carried out in program mode.
4.4.4
DELTA T FUNCTION
(
∆∆∆∆∆
T)
This function interlocks the temperature in the baking area to the temperature of the core probe.
The deviation chosen between the two temperatures (
∆
T) shall remain constant for all the baking time.
Enabling the
∆
T key, the core probe mode is automatically enabled.
The display indicates the setting of the temperature deviation of the baking area with the core probe.
Adjust the temperature
∆
T, and the core probe settings with the adjustment button.
With the
∆
T, mode, it is not possible to choose the temperature setting of the baking area.
4.4.5
COOLING THE BAKING AREA
MANUAL COOLING
In order to cool the baking area:
- Disable the baking modes;
- The temperature of the area is displayed with the arrow
↓↓↓↓↓
- Close the door and enable the START/STOP key
(the temperature is displayed)
- When the door is closed, the water injection is enabled
- You can open the door (caution! the turbine is working)
- After cooling, you can choose a baking mode again
AUTOMATIC COOLING
If the area temperature is greater than 15°C compared to the setting:
-The ventilation is forced at high speed
- The humidifier enabled to the maximum (12) (except in convection mode)
- The relief valve opens, all this in order to reach the setting temperature -10°C
4.4.6
DELAYED TURNING ON OF THE OVEN
- Choose a baking mode or a program
- Choose the delayed start (
)
-The bottom row of the display indicates the real time
-The upper row must be filled in with the starting time with the value setting button.
After confirming, the chosen time is displayed. Enable the START/STOP key. The chosen time
blinks indicating that the baking mode shall be enabled at that time. The display of the time
disappears right after setting up.
Enable the OFF key for cancelling the choice.