background image

5

Electrical Requirements

IMPORTANT: The range must be electrically grounded in 
accordance with local codes and ordinances, or in the absence of 
local codes, with the National Electrical Code, ANSI/NFPA 70, 
latest edition.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:

 National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this range be provided.

This range is equipped with a power supply cord having a 3 
prong ground plug. To minimize possible shock hazard the 
cord must be plugged into a grounded 3 prong outlet.

Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded.

This range is equipped with an electronic ignition system that 
will not operate if plugged into an outlet that is not properly 
polarized. 

The wiring diagram is located on the back of the range in a 
clear plastic bag.

NOTE: The metal chassis of the range must be grounded in 
order for the control panel to work. If the metal chassis of the 
range is not grounded, no keypads will operate. Check with a 
qualified electrician if you are in doubt as to whether the metal 
chassis of the range is grounded.

Gas Supply Requirements

Observe all governing codes and ordinances. 
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition. 
IMPORTANT: Leak testing of the range must be conducted 
according to the manufacturer’s instructions.

Type of Gas 

Natural gas:

This range is design-certified by CSA International for use with 
Natural gas or, after proper conversion, for use with LP gas. 

This range is factory set for use with Natural gas. See “Gas 
Conversions” section. The model/serial rating plate located 
behind the broiler door on the left-hand side oven door frame 
has information on the types of gas that can be used. If the 
types of gas listed do not include the type of gas available, 
check with the local gas supplier.

LP gas conversion:

Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See “Gas 
Conversions” section.

Gas Supply Line 

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to the range 
location. A smaller size pipe on longer runs may result in 
insufficient gas supply. Pipe-joint compounds that resist the 
action of LP gas must be used. Do not use TEFLON

®

 

 tape. 

With LP gas, piping or tubing size can be ½" (1.3 cm) 
minimum. Usually, LP gas suppliers determine the size and 
materials used in the system.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death, 
fire, or electrical shock.

WARNING

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

†®TEFLON  is a registered trademark of E.I. Du Pont De Nemours and Company.

Содержание MGR5605W

Страница 1: ...SITOS DE INSTALACI N 16 Piezas y herramientas 16 Requisitos de ubicaci n 16 Requisitos el ctricos 18 Requisitos del suministro de gas 18 INSTRUCCIONES DE INSTALACI N 20 Desempaque la estufa 20 Instala...

Страница 2: ...ath Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any ele...

Страница 3: ...enings in the wall or floor where range is to be installed must be sealed Do not seal the range to the side cabinets Cabinet opening dimensions that are shown must be used Given dimensions are minimum...

Страница 4: ...mm minimum IMPORTANT If installing a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances...

Страница 5: ...ional Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition IMPORTANT Leak testing of the range must be conducted according to the manufacturer s instructions Type of Gas Natural gas...

Страница 6: ...be at least 1 water column pressure above the manifold pressure shown on the model serial rating plate Line pressure testing above psi gauge 14 WCP The range and its individual shutoff valve must be...

Страница 7: ...e anti tip bracket with the screws provided Depending on the thickness of your flooring longer screws may be necessary to anchor the bracket to the subfloor Longer screws are available from your local...

Страница 8: ...y brushing on an approved noncorrosive leak detection solution Bubbles will show a leak Correct any leak found 5 Close the broiler door 6 Place burners burner caps and grates on the cooktop A Pressure...

Страница 9: ...setting a hot surface igniter heats to a bright orange and ignites the gas No sparking occurs The glow bar remains on while the burner operates Check Operation of Cooktop Burners 1 If control panel an...

Страница 10: ...k blue and should be clean and soft in character No yellow tips not enough air blowing or lifting too much air of flame should occur If the flame needs adjusting 1 Turn the oven off Wait for the oven...

Страница 11: ...burner grate burner caps and burners A To range B Manual shutoff valve closed position C Gas supply line WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut o...

Страница 12: ...tall the number 56 LP gas spud IMPORTANT Do not over tighten 6 Place Natural gas oven burner spud in plastic parts bag along with Natural gas cooktop burner spuds for future use and keep with the bag...

Страница 13: ...for top burners in the literature bag included with the range Three Natural gas spuds are stamped 149 and one 165 3 Remove the LP gas orifice spuds using a 7 mm combination wrench 4 Install the Natur...

Страница 14: ...7 Reinstall oven burner 8 Reinstall oven racks oven tray and flame spreader Complete Conversion 1 Refer to the Make Gas Connection section for properly connecting the range to the gas supply 2 Turn t...

Страница 15: ...n en este manual debe ser observada para minimizar el riesgo de incendio o explosi n o para prevenir da os a propiedades heridas o la muerte No almacene o use gasolina u otros l quidos y vapores infla...

Страница 16: ...un recinto cerrado de los lados y la parte posterior de la estufa Para eliminar el riesgo de quemaduras o incendio al tocar unidades con la superficie demasiado caliente deber evitarse el uso de armar...

Страница 17: ...rodantes necesitan Cuando se instale la estufa en una casa rodante deber asegurarse al piso durante el transporte Cualquier m todo de fijaci n es adecuado en tanto cumpla con las normas indicadas arri...

Страница 18: ...s los c digos y reglamentos aplicables IMPORTANTE Esta instalaci n debe hacerse de acuerdo con todos los c digos y ordenanzas locales Si no hay c digos locales la instalaci n deber hacerse de acuerdo...

Страница 19: ...vula de cierre La v lvula es para abrir o cerrar el suministro de gas a la estufa Regulador de la presi n de gas Deber usarse el regulador de la presi n de gas suministrado con esta estufa Para el fun...

Страница 20: ...ue la estufa de pie nuevamente sobre el cart n o madera Instalaci n del soporte anti vuelco P ngase en contacto con un instalador competente de revestimiento de pisos para ver cu l es el mejor procedi...

Страница 21: ...e anti vuelco 12 Si instala la estufa en una casa rodante deber fijar la estufa al piso Cualquier m todo de fijaci n es adecuado en tanto cumpla con las normas indicadas en la secci n Requisitos de ub...

Страница 22: ...una casa rodante deber fijar la estufa al piso Cualquier m todo de fijaci n es adecuado en tanto cumpla con las normas indicadas en la secci n Requisitos de ubicaci n 3 Contin e instalando la estufa...

Страница 23: ...ener la llama m s peque a que no se apague cuando se gire el control de un quemador fr o de HI Alto a Lo Bajo Gire hacia la derecha para reducir la altura de la llama Gire hacia la izquierda para aume...

Страница 24: ...a instalar las parrillas del horno y cierre la puerta del mismo 9 Cierre la puerta del asador Complete la instalaci n 1 Revise para cerciorarse de que todas las piezas est n instaladas Si hay alguna p...

Страница 25: ...de gas nueva con aprobaci n de CSA International Instale una v lvula de cierre Apriete firmemente todas las conexiones de gas Si se conecta a un suministro de gas LP la presi n no debe exceder una col...

Страница 26: ...s de los mismos C mo convertir el quemador del horno 1 Abra la puerta del horno y saque las parrillas charola y esparcidor de llama del horno d jelos a un lado 2 Levante el quemador del horno La espit...

Страница 27: ...1 Gire la v lvula de cierre manual a la posici n de cerrado 2 Desenchufe la estufa o desconecte el suministro de energ a 3 Abra la puerta del asador y saque la charola para asar El regulador de la pre...

Страница 28: ...apriete demasiado 6 Coloque la espita del quemador del horno de gas L P en la bolsa de piezas junto con las espitas del quemador de la superficie de cocci n de gas L P para usarlas en el futuro y gua...

Отзывы: