4-19
b) Disconnect the following wires from the
burner assembly:
• Blue and white wires from the flame
sensor terminals.
• 2-wire connector from the ignitor.
• 2-wire and 3-wire connectors from
the coil assembly.
Flame Sensor
Wht & Blu Wires
Coil Assembly 2-Wire Connector
3-Wire Connector
Ignitor Connector
c) Disconnect the gas line from the burner
manifold at the right rear corner of the
dryer.
d) Loosen the burner manifold clamp at
the inside back of the dryer.
e) Remove the two hex-head screws from
the burner mounting bracket, and pull
the burner assembly out of the unit.
Manifold Clamp Screw
Bracket Screws
f) To remove the ignitor from the burner
assembly, loosen the 5/16 inch hex-
head screw, and remove the ignitor
from the mounting bracket.
Burner Assembly
Ignitor Screw
Bracket
Continued on the next page.