6-4
TROUBLESHOOTING
TROUBLESHOOTING TESTS
NOTE: These checks are done with the dryer
unplugged or disconnected from power.
TEST #1: SUPPLY CONNECTIONS
This test assumes that proper voltage is
present at the outlet.
1.
Unplug dryer or disconnect power.
2.
Remove the cover plate from the top right
corner of the back of the dryer.
TROUBLESHOOTING GUIDE
3.
Gas Dryers Only:
a) Check that the power cord is firmly con-
nected to the dryer’s wire harness.
b) Access the electronic control board
without disconnecting any wiring to the
control board.
PROBLEM
POSSIBLE CAUSE / TEST
NOTE: Possible Cause/Tests MUST be performed
in the sequence shown for each problem.
WILL NOT POWER UP.
(
No response when Control
On button is pressed.)
1. Supply connection. See TEST #1.
2. Check harness connections.
3. Console electronics and housing. See TEST #5.
WILL NOT START CYCLE
WHEN START BUTTON IS
PRESSED.
1. If number display flashes, check to be sure the
door is completely shut, and press and hold
down HOLD TO START for about 1 second.
2. See TEST #2.
3. See TEST #6.
WILL NOT SHUT OFF
WHEN EXPECTED.
1. Check OFF/Pause button. See TEST #5.
2. Console electronics and housing. See TEST #5.
3. Moisture Sensor. See TEST #4.
CONTROL WILL NOT
ACCEPT SELECTIONS.
Console electronics and housing. See TEST #5.
WILL NOT HEAT.
1. Heater. See TEST #3.
2. Check harness connections.
3. Check installation.
HEATS IN AIR CYCLE.
Thermistor. See TEST #3a.
SHUTS OFF BEFORE
CLOTHES ARE DRY.
Moisture Sensor. See TEST #4.
Power Cord
Wire Harness
Power Cord-To-Wire Harness
Connection For Gas Dryer
Cover Plate
Remove Screw