4-10
REMOVING THE HEATER, THE HIGH-LIMIT
THERMOSTAT, & THERMAL CUTOFF
(ELECTRIC DRYERS ONLY)
1.
Unplug dryer or disconnect power.
2.
Remove the two hex-head screws from
the bottom flange of the toe panel. Pull the
panel out at the bottom, pull down, and
remove the panel.
4.
To remove the heater:
a) Remove the two wires from the termi-
nal block (see photo in step 5).
b) Remove the hex-head screw from the
heater housing, and slide the heater
out of the duct.
High-Limit Thermostat,
Thermal Cutoff, & Heater Area
3.
Remove the hex-head screw from the
heater shield and remove the shield.
Heater
Shield
Screw
Heater Housing
Screw
Toe Panel Screws
Toe Panel
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
WARNING
Содержание Epic MED/GD9600S