Connections
Connectors
© 2017 maxon motor. Subject to change without prior notice.
maxon motor control
4-34
Document ID: rel7748
EPOS2 Positioning Controller
Edition: November 2017
EPOS2 24/2 Hardware Reference
4.2.9
Encoder Connector (J11)
Figure 4-34
Encoder Connector (J11)
The use of the connector depends on the type of DC motor (respectively its connecting cable) you are
using. Possible configurations are:
A
maxon DC motor
with separated motor/encoder cable
For further details
“Motor/Encoder Connector (J3)” on page 4-29.
B
maxon DC motor
with integrated motor/encoder ribbon cable
Proceed as follows:
Figure 4-35
Controller PCB – Solder Pads (JP701 & JP702
1)
Find solder pads (
Figure 4-35, arrows) on controller PCB.
2)
Bridge
both
solder pad pairs.
3)
Connect motor/encoder ribbon cable to connector J11.
Note
With maxon DC motor
with integrated motor/encoder ribbon cable
, connector J10 will not be used!
For further details
Accessories
Cable
Encoder Cable (275934)