Motor/Hall Sensors Connector (J10)
Figure 4-33
Motor/Hall Sensors Connector (J10)
4.2.8.1
DC Motor
4.2.8.2
EC Motor
For further details
Pin
Signal
Description
1
not connected
–
2
not connected
–
3
not connected
–
4
Motor+
Motor terminal “+”
5
not connected
–
6
not connected
–
7
not connected
–
8
Motor−
Motor terminal “−”
Accessories
Cable
DC Motor Cable (303490)
Notes
Suitable connector
Suitable crimp terminals
Suitable hand crimper
Molex Micro-Fit 8 poles (430-25-0800)
Molex Micro-Fit female crimp terminals (43030-xxxx)
Molex hand crimper (63819-0000)
Pin
Signal
Description
1
Hall Sensor 3
Hall sensor 3 Input
2
Hall Sensor 2
Hall sensor 2 Input
3
Motor winding 3
Winding 3
4
Motor winding 1
Winding 1
5
+V
Hall
Hall sensor supply v5 VDC / 30 mA
6
Hall Sensor 1
Hall sensor 1 Input
7
GND
Ground
8
Motor winding 2
Winding 2
Accessories
Cable
Motor/Hall Sensor Cable (302948)
Notes
Suitable connector
Suitable crimp terminals
Suitable hand crimper
Molex Micro-Fit 8 poles (430-25-0800)
Molex Micro-Fit female crimp terminals (43030-xxxx)
Molex hand crimper (63819-0000)