CLOSING Sensing
Edge with Wireless
Module
CLOSING Photocell Beam
1B
•
REQUIRED -
AC input power wire.
•
REQUIRED -
Entrapment protection
OPENING
and
CLOSING
photocell and/or sensing edges.
•
In-ground loop wires.
Conduit Guidelines and Suggestions
Safety sensors (Photocell or contact EDGE) must be
installed in
BOTH
opening and closing direction of gate
movement where entrapment or pinch point exist.
TWO
safety sensor min. (N.C. or 10K type)
MUST
be installed or
operator will
NOT
function.
All
sensors must be UL325,
2018 compliant. See pages 7-8.
UL 325 2018 Standard
rear mounting position (alternate)
The gate must be properly installed and work freely in both directions prior to the installation of the gate operator.
The chain is not visible when looking from outside of the property.
24”
4”
V-Rail
Physical Stop
2” Gate Frame
Operator Position on Concrete Pad
Concrete Pad
24”
10.5”
10.5”
6.2”
6.75”
7.5”
7.5”
6.75”
Cover
1.5”
4”
5”
6.5”
8.625”
12.75”
Conduit
Area
Outside Property
Inside Property
Input Power
Physical Stop
Conduit
Run
Operator MUST be level.
Concrete Pad
Check local building
codes in your area for
depth of concrete
before installation.
Guide rollers
MUST
be Installed to keep gate upright.
6” above ground to avoid any flooding of the operator.
See next page for chain information.
Illustrations not to scale
Gate in Closed Position
Secure gate operator to
concrete pad with four
(4) 1/2” x 3” (min)
sleeve anchors.
Operator in Rear Position
Concrete Depth Note:
The heavier the gate, the deeper the concrete
pad should be. At least
two feet
recommended for heavier gate.
1/2
IMPORTANT:
Physical stops
MUST
be installed on
BOTH
ends of rail to
keep gate from traveling off of rail.
Wireless
Module
CLOSING
Sensing
Edge with
Wireless
Module
Wireless
Module
OPENING Photocell Beam
Photcell to
OPEN ONLY NC
Input
OPENING Sensing Edge with Wireless Module
OPENING Sensing Edge
with Wireless Module
3
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7