learn gate positions
7
1.
Push
OPEN
button to cycle gate to open position.
Operator cycles slowly while learning position.
2.
Then push
CLOSE
button to cycle gate to closed position.
Operator cycles slowly while learning position.
Gate positions have now been learned.
Gate
Shut-Off
Switch
After the virtual limits have been programmed and at least
ONE
entrapment sensor has been installed in
EACH
direction,
put the gate in the
CLOSED
position:
IMPORTANT:
GATE SHUT-OFF
Switch
MUST
be
OFF
.
(see page 14 for more information about switch)
The
ERD Sensor
-
Electronic Reversing Device
(Type A)
MUST
be adjusted for the
OPEN and CLOSE gate cycles
.
When the gate encounters an obstruction during the
CLOSE
cycle, it will reverse to the open position and
PAUSE
the gate.
An input command (press remote button or exit loop) is needed
BEFORE
the gate will reset and close again.
When the gate encounters an obstruction during the
OPEN
cycle, it will reverse approximately 6 inches and
PAUSE
the gate.
An input command (press remote button or exit loop) is needed
BEFORE
the gate will reset and open again.
For the
ERD Sensitivity
to function correctly:
•
Gate positions
must be learned
BEFORE
adjusting the ERD Sensitivity. See above.
A.
Turn knob until blue LED lights up.
Maximum sensitivity reached,
Position 1
- Too sensitive for most gates.
Position 13:
•
Typical gate setting.
B.
Turn knob
counter-clockwise
to
reduce gate sensitivity while testing ERD
until desired results is attained.
(LED remains OFF for all but position 1)
IMPORTANT:
When satisfied
with ERD adjustment, cycle
the gate 3 or 4 times to make
sure that the ERD sensor does
not
falsely trigger
during
normal gate operation.
Re-adjust if this happens.
CAUTION:
Position 16 results in gate exerting
MAXIMUM force
before reversing direction.
Adjusting ERD in EACH direction:
Typical Settings:
Position 16:
•
Heavy gate setting.
•
Long gate setting.
•
Cantilever gate setting.
•
Uphill gate setting.
•
High wind area gate setting.
Adjust ERD Reverse sensor
8
MOTION CONTROL
OPEN
STOP
CLOSE
MOTION CONTROL
OPEN
STOP
CLOSE
After gate positions have
been learned, the gate will
cycle at the speed set on
“GATE SPEED”
settings.
16 sensitivity setting positions in EACH direction.
NO mechanical hard stops for knobs.
ERD SENSITIVITY
3
1
14
12
9
7
MAX
SENSE
ERD SENSITIVITY
MIN
16
3
1
14
12
9
7
OPENING
CLOSING
ERD
MOTOR
OVER
LOAD
ERD
MOTOR
OVER
LOAD
MAX
SENSE
MAX
SENSE
ERD SENSITIVITY
MIN
3
1
14
16
MIN
16
12
9
7
3
1
14
12
9
7
MAX
SENSE
ERD SENSITIVITY
MIN
16
3
1
14
12
9
7
MAX
SENSE
ERD SENSITIVITY
MIN
16
3
1
14
12
9
7
If alarm sounds while adjusting ERD,
press
STOP BUTTON
to shut-off alarm.
MOTION CONTROL
OPEN
STOP
CLOSE
Typically set to MAX, LEDs ON.
CLOSING
OPENING
GATE SPEED
MIN
MIN
MIN
MIN
MIN
MI
M
M
MIN
MIN
MIN
MI
M
M
MAX
MAX
1
MAX
SENSE
16
MIN
CAUTION: Keep pedestrians and vehicles clear of the gate while adjusting sensors.
10
UL 325 2018 Standard - MAX 1500 PRO/2200 PRO/F18 PRO Matrix III Install Version 7