113261 - 1
69
SECTION XI
OPTIONAL SENSOR ACTIVATED
FIRE EXTINGUISHING (S.A.F.E.) SYSTEM
S.A.F.E. System In Action
The exclusive Sensor Activated Fire Extinguishing (S.A.F.E.) System will extinguish fires that may start in the drying
tumbler. A series of sensors positioned throughout the tumbler and interfaced with the microprocessor will trigger the
S.A.F.E. system water jet(s) to quickly extinguish the flames. The water jet(s) remain on for 2 minutes and will
automatically activate again if a fire condition remains or reignites. While the water jet(s) are activated, the tumbler
will jog to move the water throughout the load. The microprocessor will display that the system was activated and will
continue to display until the dryer is attended to.
We have tried to make this manual as complete as possible and hope you will find it useful. The manufacturer reserves
the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material,
and to change or discontinue models.
BEFORE YOU START!
CHECK LOCAL CODES AND PERMITS
Call your local water company or the proper municipal authority for information regarding local codes.
IMPORTANT:
It is your responsibility to have
ALL
plumbing connections made by a qualified
professional to assure that the plumbing installation is adequate and conforms to
local, state, and federal regulations or codes.
IMPORTANT:
It is the installer’s or owner’s responsibility to see that the necessary or required
water, water pressure, pipe size, or connections are provided. The manufacturer
assumes no responsibility if the S.A.F.E. system
is not
connected, installed, or
maintained properly.
WARNING:
Water
must be
supplied to S.A.F.E. system or dryer
will not
operate.
INSTALLATION
1. Requirements
The connection point to the electric water solenoid valve is a 1/2” M.P.T., the S.A.F.E. system
must be
supplied
with a minimum water pipe size of 1/2” and be provided with 40 psi (2.75 bar) and a maximum of 100 psi (6.89
bar) of pressure. For use of optional manual bypass, a second source with the same piping and pressure requirements
is required.
Содержание MAXI200
Страница 16: ...12 113261 1 1 DOOR 2 WAY TILT...
Страница 19: ...113261 1 15 1 DOOR FORWARD TILT...
Страница 22: ...18 113261 1 2 DOOR REAR TILT PASS THRU...
Страница 25: ...113261 1 21 1 DOOR 2 WAY TILT...
Страница 28: ...24 113261 1 1 DOOR FORWARD TILT...
Страница 31: ...113261 1 27 2 DOOR REAR TILT PASS THRU...
Страница 37: ...113261 1 33...
Страница 38: ...34 113261 1...
Страница 39: ...113261 1 35...
Страница 78: ...Part No 113261 1 09 20 10 0...