SECOND MAIN PAGE
From the home page, touching the navigation arrow to go to the next screen, you access to a second screen showing all
measurements carried out by the temperature probes and humidity probes in the system.
Room t.
19°C
R.H.
50%
Solar panel
temp.
75°C
Underfloor plant
t.
33°C
Sanitary water t.
37°C
Water tank temp.
48°C
Fan coil t. 1/3
28°C
CHILLER 01
Air
75°C
Water in
75°C
Water out
75°C
ZONE 03
Figure 15. Second Main page.
Referring to the figure above:
•
Field
1
indicates the zone to which you are referring. When pressed, you enter the next area, scrolling cyclically through all
the setting zones.
•
Field
2
indicates the fan coil which is referenced within the zone selected from field 1; by pressing on it the index of the
selected zone moves forward in a cyclical manner, indicating all the fan coil units in the area. The detected air probe
temperature is displayed for each fan coil. These indications appear only if there are fan coils configured in the system.
•
Field
3
indicates the chiller referred to; by pressing on it, you progress to all the other chillers in the network. For each
chiller shown, you see the readings of the water inlet and outlet temperatures of the chiller and the air temperature
measured by the probes on board.
•
Field
4
shows the ambient temperature and the relative humidity measured by the probes integrated in the Hi-T2 panel.
•
Field
5
indicates the presence of the solar panel system; then the indication on the temperature of the solar panels is
shown. These indications appear only if a solar panel system is configured in the system.
•
Field
6
shows the enabling of domestic hot water production related to the selected chiller. It indicates the temperature of
the domestic hot water produced.
•
Field
7
indicates the presence of a storage tank connected to the selected chiller. The display will show the temperature of
the plant storage tank when enabling the water system remote probe. Whereas it will show the temperature of the DHW
tank if the domestic hot water production is activated. If solar management is activated, it will display the temperature of
the solar storage tank.
•
Field
8
indicates the presence of radiant floor panels; this field is linked to the enabling of the double setpoint function.
In the case of faulty probes or not properly configured and/or connected, the error warning appears.
NOTE
: The presence of DHW tank refers to the fact that there is a heat pump enabled in the DHW mode in the network.
3.6
SYSTEM MAIN PAGE
From the second page, touching the navigation arrow to the next screen, you go to a third screen for general settings, the "system
main page", showing the following functional icons:
Figure 16. System main page.
5
7
4
1
2
8
Sanitary water t.
37°C
Fan coil t. 1/3
Water tank temp.
CHILLER 01
Room t.
R.H.
Air
Water in
Water out
ZONE 03
3
6