Temperature Controller METICOM CTI Series
6) In the control process, when the start trigger ends, the gate open/close cycle will be terminated
and gate close.
7) The controller waits a new start trigger.
Mode 2: The gate open/close cycle will be terminated and gate close when the new start trigger
comes.
The controller initializes the run timer when it receives the new start trigger.
1) When the controller receives the start trigger, it starts the run timer from the zero time position.
2) Gates open after T1 time (or screw position is T1) from the controller receives start trigger;
3) Gates close after T2 time (or screw position is T2) from the gates open;
4) Gates open again after T3 time (or screw position is T3) from the gates close;
5) Gates close after T4 time (or screw position is T4) from the gates open;
6) In the control process, when the new start trigger comes, the gate open/close cycle will be
terminated and gate close.
At the same time, the controller initializes the run timer to start a new gate open/close cycle.
Mode 3: The gate open/close cycle will be terminated and gate close when the new start trigger
comes.
The controller initializes the run timer when it receives the next new start trigger.