Page | - 36 -
© Copyright Mastip Technology Limited. Information subject to alteration. V1.01 www.mastip.com
Temperature Controller METICOM CTI Series
6.6.2.3 Select the Curve Start Time
When you enter the History Curve Screen, the curve start time is 2 hours ago.
You can click the Start Time to input a new one (the time format should be same as the original one).
And you can select the start time by
Select a specified time.
Forward 0.5 hour based on the curve Backward 0.5 hour based on the curve
Forward 1.0 hour based on the curve Backward 1.0 hour based on the curve
Forward 2.0 hour based on the curve Backward 2.0 hour based on the curve
6.6.2.4 Zoom In & Zoom Out the Curve
You can adjust the scale of X/Y axis with the sliding bar, to zoom in or zoom out the curve.
6.6.2.5 View Other Zones
You can view the history curve of other zones by touching [PgDn] or [PgUp].
In the first page, you will see the [Present] used to back to present curve screen.
6.6.2.6 Export the Historical Data
You can export the historical data record (in csv format) to USB disk by touching [Export].
Notes:
Only supports USB disks that use a File Allocation Table (FAT or FAT32) format.
Only supports USB versions 2.0 and 1.1.
Use an empty USB disk or one that contain as few files as possible.
Do not remove the USB disk from the system during the writing operation.
6.6.2.7 Back to Present Curve
Touch the [Quit] to go back to the present curve screen.