Page | - 3 -
© Copyright Mastip Technology Limited. Information subject to alteration. V1.01 www.mastip.com
Temperature Controller METICOM CTI Series
Each CTI-M2 temperature control module comes standard with two zones at 15amps per zone.
Each CTI-V2 sequential valve gate control module can control up to six valve gates each module. One
or more power control modules are also required to supply power requirements to the system
solenoid valves. The position and quantity of power control modules and valve gate control modules
in the mainframe are configured depending on the initial specification request, and are fixed to the
specific slot position.
1.3 Specifications
Model
CTI-100
CTI-200
CTI-300
User Interface
Full color LCD touch screen
Display Size
7.0" / 10.2"
10.2"
Max. Total Zones
32
80
120
Max. Temp. Zones
32
80
120
Max. Sequential Zones
24
24
Power Supply
3-Ph+E (4 wire) 200-240Vac
3-Ph+N+E (5 wire) 380-415Vac
Working Conditions
0~55
℃
(32~131
℉
), 10~80%RH (No condensing)
Storage Conditions
-20~70
℃
(-4~158
℉
), 10~80%RH (No condensing)
Temperature Control
(1) Power indicator:
green
light when powered on.
(2)&(3) Zone A & Zone B status indicator:
green
– stop;
red
– running;
blink fast – communicating with HMI;
green
/
red
alternately: alarm
(1)
Power indicator.
(2)
Injection signal indicator.
CTI-M2
CTI-V2