Function Button:
Icon mode is default setting. Text mode can be selected on system setting page.
●
24 or 42 zones per page:
24-zone is the default setting, but can be changed on system setting page.
●
Resolution:
1 is the default setting, 0.1 can be selected on system setting page.
⑴
Zone number.
⑵
Zone status: alarm information is in
red
, e.g. No.2 zone.
⑶
Actual Temperature (PV):
●
resolution 0.1 can be selected on system setting page.
●
displayed in
red
in stop state, e.g. No.3 zone.
●
if thermocouple is open, 999 is displayed, e.g. No.2 zone.
●
if zone is turned off,
OFF
is displayed in red, e.g. No.4 zone.
●
reading blinks if there is a communication failure.
●
click the PV value to set a zone’s parameters and operate it.
⑷
Setpoint (SV):
●
temperature unit can be selected between
Celsius and Fahrenheit
by Engineer’s security login.
●
displayed in
red
in stop state, e.g. No.3 zone.
●
output percent setting will be displayed in manual mode, e.g. No.1 zone.
●
click setting value, output percent and load current can be alternated to show in 42-zone
page.