Page | - 40 -
© Copyright Mastip Technology Limited. Information subject to alteration. V1.01 www.mastip.com
Temperature Controller METICOM CTI Series
Chapter 7 Sequential Valve Gate Control Operations
Touch [
SVG
] on Temperature Control main interface, then you can enter Sequential Valve
Gate Control main interface.
And touch [
Temp
] on Sequential Valve Gate Control main interface, then you can enter
Temperature Control main interface.
Notes: 1) Zone’s output type is selected on modules with jumpers.
2) Input Screw position unit can be mm or inch, selected in screw position’s setup (calibration).
7.1 Control Modes
[
Auto
]
:
This type of control is an auto system and requires a start trigger signal.
The controller will wait until it receives the start trigger after which it starts the timer from zero time
position. From this point gates open and close according to the time or position settings that you have
configured.
[
Manual
]
:
This type of control requires no start trigger signal.
Each gate can be opened or closed by touching [MANUAL].