JOINT 1 CALIBRATION
ACTION
IMAGE
Move the hose connecting the two
sections of the arm (if required, re-
move a fastening clip and remove the
hose from one of the pipe ends);
Insert the socket spanner (dwg. 2) in
the recess housing the spring and
fit it on the calibration nut. Insert a
screwdriver from the side through
the socket spanner and follow the
instructions below.
Turn the calibration tool
CLOCKWISE
.
To
INCREASE
the effort required by the operator to
take the arm to the
EXTENDED
position and
DECREASE
the effort required by the operator to
return the arm to the
RETRACTED
position at the
same time.
Turn the calibration tool
ANTI-
CLOCKWISE
To
INCREASE
the effort required by the operator
to take the arm to the
RETRACTED
position and to
DECREASE
the effort required by the operator to
return the arm to the
EXTENDED
position at the same
time.