6
CE Regulation use and maintenance manual
IT IS FORBIDDEN TO EVEN PARTIALLY REPRODUCE THE TEXT AND/OR ILLUSTRATIONS.
www.masterweld.co.uk
2.
SAFETY INFORMATION
Carefully read the instructions in this manual and those applied directly on the machine.
2.1. RESIDUAL RISKS
RESIDUAL RISK
DESCRIPTION
Voltage hazard
Maintenance operations performed on live machine electrical parts entail the
risk of electrocution.
Danger of crushing upper
limbs
Closing mobile elements with cam locks poses the risk of crushing fingers.
Dust inhalation danger
Maintenance operations performed inside the machine entail the risk of
inhaling potentially carcinogenic dust.
Fire risk
Routine operations performed despite the prohibition expressed in
"7.1.
RECOMMENDATIONS FOR MAINTENANCE INTERVENTIONS"
.
Maintenance operations operations performed despite the prohibition
expressed
in
"7.1.
RECOMMENDATIONS
FOR
MAINTENANCE
INTERVENTIONS".
Explosion risk
Routine operations performed despite the prohibition expressed in
"7.1.
RECOMMENDATIONS FOR MAINTENANCE INTERVENTIONS"
.
Maintenance operations operations performed despite the prohibition
expressed
in
"7.1.
RECOMMENDATIONS
FOR
MAINTENANCE
INTERVENTIONS".
Cutting hazard
Maintenance operation performed without the use of protective gloves for the
removal of moving sheet metal parts entails the risk of cutting fingers.
2.2. GENERAL SAFETY WARNINGS
Personnel performing any type of intervention throughout the machine life-span, must have precise technical
skills, special abilities due to acquired and recognised experience in the specific sector, be trained on how to
use the necessary work tools and appropriate personal protective equipment, with reference to the applicable
laws and in force in the place of use of the machine. Lacking these requirements may cause damage to people's
health and safety. Use the personal protective equipment indicated in the manual.
In the EXTRACTION FAN version
The machine contains potentially explosive dust deposits and/or gases, therefore it is forbidden to
approach or introduce in the machine any possible ignition source:
• Naked flames
• Hot surfaces
• Sparks
• Gas
• Live electrical parts
• Electrostatic charges
2.3. SAFETY WARNINGS FOR HANDLING, ASSEMBLY AND INSTALLATION
Use adequate lifting equipment for handling and adopt all the safety precautions designed for activities carried
out in the work site.
In the EXTRACTION FAN version
The electrostatic charge accumulated by the flexible pipes might ignite a fire. Therefore, they must
have electrical conductivity and be earthed.
In the EXTRACTION FAN version
The machine must be installed in an area where there is no explosive atmosphere.