43
CE Regulation use and maintenance manual
IT IS FORBIDDEN TO EVEN PARTIALLY REPRODUCE THE TEXT AND/OR ILLUSTRATIONS.
www.masterweld.co.uk
7. MAINTENANCE INFORMATION
7.1. RECOMMENDATIONS FOR MAINTENANCE INTERVENTIONS
Carefully read the instructions in this manual before any maintenance intervention.
Perform maintenance activities using the personal protective equipment described in the
manual.
Always wear suitable footwear in order to avoid electrostatic discharges before carrying out
any maintenance intervention.
In order to avoid the risk of fire or explosion, never smoke or use open flames inside
or in the vicinity of the filter during maintenance or cleaning operations.
7.2. TABLE OF SCHEDULED MAINTENANCE INTERVALS
Routine maintenance operations are to be performed at the date shown in the table..
It is advised to keep a maintenance register in order to keep a trace of the interventions
performed.
OPERATION
VERY FREQUENT
FREQUENT
NOT FREQUENT
2
4
h
o
u
rs
2
5
0
h
o
u
rs
5
0
0
h
o
u
rs
1
0
0
0
h
o
u
rs
Y
e
a
rl
y
Check correct calibration of the filtering
arm
•
Check
conditions
of
flexible channel
sections
•
Replace mandatory the flexible channel
sections with flexible hoses providing the
same physical features
•
Check wear of suction hood joints and
hood clutches
•
Check wear of slewing bearing
•
Check the cleaning of the inlet piping
going to the filer. including hoods, flexible
pipes.
•
Check conditions of internal adjustment
shutter
•