ENTREE BATH TRAINING CHECK LIST 

After reviewing the operation and safety instructions in this manual, the Entree Bath can be operated and all components 

can be identified. 

OPERATION: 

YES 

NO 

Turn On BathAire

(SM)

 Control 

 

 

Move Individual Into The Entree Bath  

 

 

Secure Individual 

 

 

Close Tub Door With Push Buttons 

 

 

Close Drain With Open/Close Lever 

 

 

Adjust Mixing Valve To Desired Temperature 

 

 

Fill Tub with Tub Fill Valve 

 

 

Use Liquids As Desired 

 

 

Use Shower Wand With Shower Wand Control Valve 

 

 

Open Drain With Open/Close Lever 

 

 

After Water Is Drained, Open Tub Door With Push Buttons 

 

 

Move Individual Out Of The Entree Bath 

 

 

Return Individual To Room Or Desired Location 

 

 

Remove Comfort Pads And Place In Foot Well 

 

 

Use Disinfectant To Clean Tub And Pads 

 

 

Rinse Disinfectant From The Tub And Pads 

 

 

 

 

 

LOCATE & IDENTIFY: 

 

 

LCD Thermometer 

 

 

GFCI reset 

 

 

Aromatherapy Access Cap & Canister 

 

 

Wall Chart 

 

 

T-Handle Allen Wrench 

 

 

Casual Water Drain 

 

 

 

 

Training Date: 
Staff: 
Supervisor: 

Please, make copies of this training checklist for each staff member that will operate the Entree Bath. 

 

Содержание Gen II Entree Bath

Страница 1: ...All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The caution heading identifies important maintenance and operation information Failure to...

Страница 2: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 20 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Страница 3: ...ir dryer lamp telephone radio or television within 5 ft 1 5m of the hydromassage bathtub Proper electrical grounding must be performed by a licensed electrician following local state and federal codes...

Страница 4: ...ll and Shower Spray Control Valves Turns ON OFF and controls the flow of mixed water to the tub Fill Spigot and Shower Wand Solar Powered Thermometer Digital readout temperature of the mixed water to...

Страница 5: ...utton once and BathAire SM will turn on Press the button once again and the BathAire SM will shut off BathAire SM More Less Air Heat Buttons Once the BathAire SM is on it is in an adjustment mode Bath...

Страница 6: ...out of the way Position the comfort pad group as follows two rectangular pads parallel about three to four inches apart centered in the individual seating area and one rectangular pad horizontally on...

Страница 7: ...the Dispensing bottle This will help reduce foaming from soap shampoo etc CAUTION If there is water in the tub the drain sensors will not let the Door Switch be activated This will prevent accidental...

Страница 8: ...BathAire SM system 10 Dry as much of the individual as you can before removing them from the tub by leaning the individual forward and towel dry their back side and inside of the tub area behind the...

Страница 9: ...ttended during the entire bathing procedure B All individuals must be assessed before using the system to determine if they will require the assistance of two staff members to transfer into and out of...

Страница 10: ...fer device is needed 11 Push down on the Door Open Button allowing the door to rotate to a fully open position until it stops on its own 12 Remove the Kick Panel by removing the two thumb screws at ei...

Страница 11: ...cases the door can be opened with the yellow handled 5 16 ball end Allen wrench driver see also GFCI Reset Procedures 3 Remove the emergency door open close access panel by removing the two thumb scr...

Страница 12: ...and reset using the following procedures GFCI Ground Fault Circuit Interrupter detects and interrupts electric faults to insure safety to all individuals Reset Button trips and shuts down all power sh...

Страница 13: ...e pad as far as they go Pull gently up on one side until all the cups release CAUTION Do not pull up on pad by grasping it on the outside and trying to pull up on all suction cups at the same time wit...

Страница 14: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 32 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Страница 15: ...Adjust Mixing Valve To Desired Temperature Fill Tub with Tub Fill Valve Use Liquids As Desired Use Shower Wand With Shower Wand Control Valve Open Drain With Open Close Lever After Water Is Drained O...

Страница 16: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 34 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Отзывы: