Generation II Entree Bath
– All Models
OPERATION MANUAL
07-01-2018
Page 28 of 50
2071 14
th
Ave – Columbus, NE 68601
800-798-5867 FAX: 402-563-9102
www.mastercarebath.com
ADJUSTING THE ENTREE TUB FOR LIFT/TRANSFER DEVICES
For those cases when a lift/transfer device is needed:
11.
Push down on the Door Open Button
allowing the door to rotate to a fully open position until it stops on its own.
12.
Remove the Kick Panel
by removing the two thumb screws at either end of the panel.
Note
: Clearance distance under the tub when the Kick Plate is removed for lift/transfer devices: 3.5"
CAUTION
:
Do not use equipment with bases equal to or greater than 3.5". Damage to tub may occur.
Thumb Screw
Thumb Screw
Kick Panel