Generation II Entree Bath
– All Models
OPERATION MANUAL
07-01-2018
Page 23 of 50
2071 14
th
Ave – Columbus, NE 68601
800-798-5867 FAX: 402-563-9102
www.mastercarebath.com
FOOT-END CONTROL PANEL:
Emergency Door Open Button:
In the case of an emergency, hold the
Emergency Door Open Button and the Door Open Button
at the same time
to
open the door
.
It will override the drain water sensors.
BathAire
(SM)
Control:
See Basic Operation.
Door Open/Close Button:
To open door, press and hold down the Door Open
Button until the door comes to a complete stop. To close the door, press and
hold down the transmitter close button until the door comes to a complete
stop.
CAUTION:
Check for obstructions in the sensors, like wet wash cloth,
foot, etc.
CAUTION:
Door will not open if drain sensors detect water in the tub
unless the Emergency Door Open Button is also pressed at the same
time.
CAUTION:
Make sure the door comes to a complete stop to properly seal
the tub. Failure to do so may result in leaks. Contact Tech Support.
Thumb Screws:
The thumb screws hold the service panel in place and are to
be removed only by authorized service personnel for service access.
BATHAIRE
(SM)
VARIABLE SPEED SYSTEM CONTROL BASIC OPERATION:
BathAire
(SM)
On/Off Button:
The BathAire
(SM)
can be turned on or off by pressing the on/off button. Press the button once
and BathAire
(SM)
will turn on. Press the button once again and the BathAire
(SM)
will shut off.
BathAire
(SM)
More & Less Air/Heat Buttons:
Once the BathAire
(SM)
is on, it is in an adjustment mode. BathAire
(SM)
turns on
at 60% of full volume. To increase or decrease the air volume, press the more or less air/heat button and hold down until
the desired level is achieved. The heat level is tied to the air volume and adjusted the same way.
BathAire
(SM)
Wave Mode:
To create a wave effect: Press the wave button once for the long cycle, a second time for the
short cycle and a third time to return to normal operation. This will automatically increase and decrease the air volume
through the bath cycle.
BathAire
(SM)
Purge Cycle:
The purge cycle comes on automatically 20 minutes after the BathAire
(SM)
system has been
turned off. It will then run for a period of one minute. This is a preset of the motor and cannot be turned off. It also is
programmed to cycle every 24 hours, so be aware it will run the purge cycle 24 hours after BathAire
(SM)
being energized.
BathAire
(SM)
Internal Timer:
The BathAire
(SM)
system has an internal timer that shuts the BathAire
(SM)
off automatically
after it has run for twenty minutes. If it get turned off in the middle of a bath, it can be turned back on. The Purge cycle
will also operate 20 minutes after time shut off.
BathAire
Control Panel
Door Close
Door Open
Emergency
Door Open
Thumb Screw
Thumb Screw
Door Close
On/Off Button
More Air/Heat
Button
Less Air/Heat
Button
Wave Button