background image

Generation II Entree Bath

  All Models 

OPERATION MANUAL 

  

07-01-2018 

Page 32 of 50

 

2071 14

th

 Ave – Columbus, NE 68601 

800-798-5867  FAX: 402-563-9102 

www.mastercarebath.com

 

 

 

 

This page is intentionally left blank 

Содержание Gen II Entree Bath

Страница 1: ...All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The caution heading identifies important maintenance and operation information Failure to...

Страница 2: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 20 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Страница 3: ...ir dryer lamp telephone radio or television within 5 ft 1 5m of the hydromassage bathtub Proper electrical grounding must be performed by a licensed electrician following local state and federal codes...

Страница 4: ...ll and Shower Spray Control Valves Turns ON OFF and controls the flow of mixed water to the tub Fill Spigot and Shower Wand Solar Powered Thermometer Digital readout temperature of the mixed water to...

Страница 5: ...utton once and BathAire SM will turn on Press the button once again and the BathAire SM will shut off BathAire SM More Less Air Heat Buttons Once the BathAire SM is on it is in an adjustment mode Bath...

Страница 6: ...out of the way Position the comfort pad group as follows two rectangular pads parallel about three to four inches apart centered in the individual seating area and one rectangular pad horizontally on...

Страница 7: ...the Dispensing bottle This will help reduce foaming from soap shampoo etc CAUTION If there is water in the tub the drain sensors will not let the Door Switch be activated This will prevent accidental...

Страница 8: ...BathAire SM system 10 Dry as much of the individual as you can before removing them from the tub by leaning the individual forward and towel dry their back side and inside of the tub area behind the...

Страница 9: ...ttended during the entire bathing procedure B All individuals must be assessed before using the system to determine if they will require the assistance of two staff members to transfer into and out of...

Страница 10: ...fer device is needed 11 Push down on the Door Open Button allowing the door to rotate to a fully open position until it stops on its own 12 Remove the Kick Panel by removing the two thumb screws at ei...

Страница 11: ...cases the door can be opened with the yellow handled 5 16 ball end Allen wrench driver see also GFCI Reset Procedures 3 Remove the emergency door open close access panel by removing the two thumb scr...

Страница 12: ...and reset using the following procedures GFCI Ground Fault Circuit Interrupter detects and interrupts electric faults to insure safety to all individuals Reset Button trips and shuts down all power sh...

Страница 13: ...e pad as far as they go Pull gently up on one side until all the cups release CAUTION Do not pull up on pad by grasping it on the outside and trying to pull up on all suction cups at the same time wit...

Страница 14: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 32 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Страница 15: ...Adjust Mixing Valve To Desired Temperature Fill Tub with Tub Fill Valve Use Liquids As Desired Use Shower Wand With Shower Wand Control Valve Open Drain With Open Close Lever After Water Is Drained O...

Страница 16: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 34 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Отзывы: