background image

Generation II Entree Bath

  All Models 

OPERATION MANUAL 

  

07-01-2018 

Page 24 of 50

 

2071 14

th

 Ave – Columbus, NE 68601 

800-798-5867  FAX: 402-563-9102 

www.mastercarebath.com

 

OPERATION 

Before operating the Entree Bath, familiarize yourself with the 

key features of the tub outlined in the drawings supplied with 

these instructions (Video provided in the tub kit and viewable 

on MasterCare website). 

1.

 

If Aromatherapy is desired, place selected  scent sachet or 

canister in the Aromatherapy holder

  and securely close the 

access cap prior to turning on BathAire

(SM)

(See Aromatherapy 

Section in this manual)

 

CAUTION:

 

Do NOT remove beads from sachet. Never 

place liquids in the Aromatherapy sachet holder.

 

2.

 

Turn On The BathAire

(SM)

 

by pushing in on the BathAire

(SM)

 On/Off 

Touch Pad located on the lower left side deck of the tub. This will 

warm up the environment inside the tub. You can increase or 

decrease the air flow by pushing down on the plus (+) or minus (-) 

section of the touch pad. 

3.

 

Place Individual into Entree Bath:

 

The Entree Bath operator must be trained by qualified facility 

personnel. Recommended manufacturers procedures must be 

utilized before they can be allowed to operate the Entree Bath 

system. Refer to provided Video.  

Verify door is in the fully opened position.  Position the security 

belt attached to the security belt knob on top of the tub deck and 

move it out of the way. Position the comfort pad group as follows: 

two rectangular pads parallel about three to four inches apart, 

centered  in the individual seating area and  one rectangular pad 

horizontally on the seat back at approximately the lumbar area of 

the individual 

(see  Aromatherapy, Comfort Pad and Belting 

Procedures 

section

)

 Transfer the individual onto the Entree Bath 

seat using appropriate ergonomic transfer techniques or with a 

modern lift/transfer device per facility protocol (Refer to section 

Adjusting Entree Tub for Lift/Transfer Device

  section in this 

manual

)

  Make sure the individual's feet are positioned in the 

center of the foot well. 

The grab bar is intended for transferring, NOT for load bearing. 

Use the grab bar only for stabilizing, NOT standing. Make sure 

the individual's feet and hands are clear of all areas where the 

door meets the outside tub surface during the closing procedure. 

Never let a bather stand in the foot well! 

4.

 

Secure the Individual:

 

Secure the security belt firmly around the individual's chest by 

inserting the security belt  knob located behind the individual's 

back through the appropriate hole at each end of the belt. Adjust 

the belt and comfort pads as necessary for the individual's security 

and comfort 

(

see  Aromatherapy, Comfort Pad and Belting 

Procedures 

section, in this manual

). 

Security Belt 

BathAire Variable 

Speed Control 

Door Close 

Button 

Door Open 

Button 

Comfort Pads 

Emergency 

Door Open 

On/Off Button

 in BathAire

(SM)

 

Variable Speed Control 

Aromatherapy 

Access Cap 

Security Belt 

Knob 

Security Belt Knob 

Содержание Gen II Entree Bath

Страница 1: ...All Instructions Thoroughly Important safety instructions Read and follow all instructions thoroughly CAUTION The caution heading identifies important maintenance and operation information Failure to...

Страница 2: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 20 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Страница 3: ...ir dryer lamp telephone radio or television within 5 ft 1 5m of the hydromassage bathtub Proper electrical grounding must be performed by a licensed electrician following local state and federal codes...

Страница 4: ...ll and Shower Spray Control Valves Turns ON OFF and controls the flow of mixed water to the tub Fill Spigot and Shower Wand Solar Powered Thermometer Digital readout temperature of the mixed water to...

Страница 5: ...utton once and BathAire SM will turn on Press the button once again and the BathAire SM will shut off BathAire SM More Less Air Heat Buttons Once the BathAire SM is on it is in an adjustment mode Bath...

Страница 6: ...out of the way Position the comfort pad group as follows two rectangular pads parallel about three to four inches apart centered in the individual seating area and one rectangular pad horizontally on...

Страница 7: ...the Dispensing bottle This will help reduce foaming from soap shampoo etc CAUTION If there is water in the tub the drain sensors will not let the Door Switch be activated This will prevent accidental...

Страница 8: ...BathAire SM system 10 Dry as much of the individual as you can before removing them from the tub by leaning the individual forward and towel dry their back side and inside of the tub area behind the...

Страница 9: ...ttended during the entire bathing procedure B All individuals must be assessed before using the system to determine if they will require the assistance of two staff members to transfer into and out of...

Страница 10: ...fer device is needed 11 Push down on the Door Open Button allowing the door to rotate to a fully open position until it stops on its own 12 Remove the Kick Panel by removing the two thumb screws at ei...

Страница 11: ...cases the door can be opened with the yellow handled 5 16 ball end Allen wrench driver see also GFCI Reset Procedures 3 Remove the emergency door open close access panel by removing the two thumb scr...

Страница 12: ...and reset using the following procedures GFCI Ground Fault Circuit Interrupter detects and interrupts electric faults to insure safety to all individuals Reset Button trips and shuts down all power sh...

Страница 13: ...e pad as far as they go Pull gently up on one side until all the cups release CAUTION Do not pull up on pad by grasping it on the outside and trying to pull up on all suction cups at the same time wit...

Страница 14: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 32 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Страница 15: ...Adjust Mixing Valve To Desired Temperature Fill Tub with Tub Fill Valve Use Liquids As Desired Use Shower Wand With Shower Wand Control Valve Open Drain With Open Close Lever After Water Is Drained O...

Страница 16: ...eneration II Entree Bath All Models OPERATION MANUAL 07 01 2018 Page 34 of 50 2071 14th Ave Columbus NE 68601 800 798 5867 FAX 402 563 9102 www mastercarebath com This page is intentionally left blank...

Отзывы: