Fitting the front liner
•
Push the front liner into position, pushing evenly at both ends so that it does not jam. The anti-
rotation pins within the pump housing (arrowed) guarantee that the liner is properly positioned.
The two liners are identical.
Fitting the front cover
•
Check that the front cover O-ring (arrowed) is in its groove in the front cover.
•
Fit the front cover over the shaft, the front support and the pump housing studs.
•
Fit the cap nuts (right-hand thread) and washers to the pump housing studs. Use a 22mm spanner.
Tighten them to 45Nm (torque for other sizes see "Tightening torques" on page 89)
Assembling the pump housing— pumps with a stainless steel power frame and a single
mechanical seal
Note
: See " Fitting the pump housing—pumps with a single mechanical seal" on page 76 for assembling
the pump housing of a pump with a cast iron power frame.