Use the special tools supplied with the pump to remove the seal housing.
•
Position the pointed ends of the special tools to apply leverage to opposite sides of the seal
housing at once: first, to the castellations of the seal housing; then to the end of the seal housing.
First
leverage
point
Second
leverage
point
Second
leverage
point
Direction of
movement
•
Reverse the special tools and use the angled ends in the same way to apply further leverage to the
end of the seal housing, until it is accessible within the pump chamber. Remove it.
The two versions of the SPS 100 pump seal housing: left,
where no static flushing system is fitted; right, where a
static flushing system is fitted
Disassembling the seals
•
Graphics making clear how to disassemble and assemble the seals appear in section "Seals" on
42
m-SPS-en-08