![masosine SPS 100 Скачать руководство пользователя страница 35](http://html.mh-extra.com/html/masosine/sps-100/sps-100_user-manual_1735328035.webp)
•
If this dimension is not correct, continue disassembly (see "Disassembly and assembly" on
page 38) until the face of the power frame is accessible (the SPS 300 and the SPS 200 pumps are
shown here; the SPS 400 is similar).
•
Use a 6mm Allen key to loosen and remove the bearing housing retaining screws and copper
washers (arrowed; the number of screws varies with pump model.)
•
Remove the bearing housing and the pump shaft, being careful not to damage the lip seals
(arrowed). Note: lubricating oil will spill out as the bearing housing is removed.
•
Remove the shim ring (arrowed in the three lower pictures) and install a new one. Reassamble,
tightening the bearing housing retaining screws to 25Nm (SPS 200) 50Nm (SPS 300) 35Nm (SPS
400), and measure dimension X again.
•
If this dimension is not correct, disassemble and peel layers from the shim ring equal in total
thickness to the difference between the-re-measured distance and the correct distance, so that the
correct dimension X is achieved. One layer is 0.05mm thick.
•
Reassemble.
m-SPS-en-08
35
Содержание SPS 100
Страница 16: ...9 1 Dimensions in millimetres SPS 100 16 m SPS en 08 ...
Страница 92: ...25 1 Pumps SPS 100 92 m SPS en 08 ...
Страница 95: ...SPS 200 with cast iron power frame m SPS en 08 95 ...
Страница 98: ...SPS 200 with stainless steel power frame 98 m SPS en 08 ...
Страница 101: ...SPS 250 with stainless steel power frame m SPS en 08 101 ...
Страница 104: ...SPS 300 with cast iron power frame 104 m SPS en 08 ...
Страница 107: ...SPS 300 with stainless steel power frame m SPS en 08 107 ...
Страница 110: ...SPS 400 with cast iron frame 110 m SPS en 08 ...
Страница 113: ...SPS 400 with stainless steel frame m SPS en 08 113 ...
Страница 116: ...SPS 500 with stainless steel power frame 116 m SPS en 08 ...