FLAT BAR SHEARING STATION SPARTAN IRONWORKER
H-8
© MARVEL MFG. CO., INC. MANUAL
PL/OMIW-2CYL-V2
(08//07)
Do not operate the machine unless:
a.
You are familiar with the function
and location of the machine's
components.
b.
You have inspected the machine and
determined it is in safe, working
condition (for example: no missing,
altered or broken parts; all controls
are functional; all safety devices are
in place; etc.).
c.
You have read and understand all
of the safety and instructional
material supplied with the machine
by Marvel Mfg. Co., including the
Operator's manual and the safety
and warning signs attached to the
machine.
Pre-Operation Checklist
This checklist must be completed at the beginning
of each shift and by each operator.
o
Safety First! Obey all warnings.
o
Review and comply with the instructional
and safety information provided with this
machine.
o
Turn the machine's power off with the main
electrical disconnect switch and lock it in
the "Off" position.
o
Make sure all guards and covers are in place
and function properly.
Avoid serious injury.
Do not operate this machine
with
missing,
altered,
or
defective guards or covers.
o
Remove unnecessary tools and equipment
from the machine and surrounding area.
o
Inspect the machine for damage, leaks, and
alterations. Repair before operating.
Avoid serious injury.
Do not operate this machine if
it is damaged, has worn or
missing parts, or is altered in
any way.
o
Check the hydraulic fluid level. Fill if
needed.
Never operate the machine with
a low hydraulic fluid level.
o
Damage to the machine will
occur.
Flat Bar Shear Set-up
The following steps must be performed for each
flat bar shearing operation.
1.
Perform the pre-operation checklist on
page H-7.
2.
Position the following switches as
indicated:
o
Auto / Manual switch to "Manual".
o
Shear / Notch switch to "Shear".
o
Normal / Jog switch to "Jog".
o
Press the Emergency Stop pushbutton.
3.
Make sure the notching station's guard is
closed.
4.
Turn on the Main Electrical Disconnect
switch.
5.
Reset the Emergency Stop pushbutton(s).
6.
Press the "Pump On' pushbutton.
Note: If the hydraulic pump does not come on
make sure the Emergency Stop pushbutton(s) are
reset.
WARNING
WARNING
CAUTION