ANGLE SHEARING STATION
SPARTAN IRONWORKER
F-9
© MARVEL MFG. CO., INC. MANUAL
PL/OMiW-2CYL_V2
(08/07)
Avoid serious injury. Turn off
the machine's power and lock
it out before adjusting the
stationary blades.
9.
Turn off the main electrical disconnect
switch and lock it in the "Off" position.
10.
Measure the clearance between the shear's
blades. The clearance must be within the
range specified in the chart, below. If the
clearance is correct, continue with step 14.
If the clearance is incorrect, continue with
step 11.
Measure the clearance between the blades with a
feeler gauge. The blades should have a uniform
clearance within the range defined in the chart,
below.
SHEAR BLADE CLEARANCE
Model: Clearance:
IW66D, IW88D .008” -.01”
IW110D/2,IW135D, IW180DX .01” - .014”
11.
Loosen the 4 socket head cap screws (B
and C).
Two socket head cap screws (C and B) lock each
of the stationary blades in place. Screws "G" and
"F" are used to adjust the clearance between the
moveable blade and the stationary blades. Each
of these screws is locked in position by a hex nut.
12. Loosen the hex nuts which lock the screws (G
and F) in position.
13.
Adjust screws "G" and "F" as needed to
obtain a uniform clearance within the
range defined in the chart. To do this:
a.
Turn
screws
"G"
and
"F"
clockwise
to
decrease
the
clearance between the blades.
b.
Turn screws "G" and "F" counter-
clockwise to increase the clearance
between the blades.
14.
Tighten screws "C" and "B" and recheck
the clearance between the blades. Repeat
steps 11 through 13 as needed.
Avoid injury. The guard weighs
22 lbs. Use care when lifting
and installing the guard.
15.
Re-install the guard removed in step 2.
WARNING
CAUTION
G
F
C
B