Maintenance
- The machine must be placed to
allow easy access to all areas for maintenance and
repairs. Make sure all doors and panels can be
opened easily.
LEVELING AND ANCHORING
Four leveling screws (A) are provided to level the
machine. After the machine has been leveled the
position of each leveling screw can be locked in
place with the lock screw (B) provided on each
leveling screw.
Anchoring bolts can be installed if needed.
Anchor the machine to the floor by drilling holes
in the floor through the four holes in the
machine's base (C) and installing anchor bolts,
washers, and nuts.
Leveling screw (A), locking screw (B), and anchor bolt hole
(C).
ASSEMBLY
The Ironworker is shipped fully assembled with
the exception of the electric back gauge. To
assemble the back gauge:
1.
Attach the length rod (A) to the discharge
side of the machine with the three screws
provided (B).
Assembling the electric back gauge.
2.
Slide the collar (C) onto the length rod.
3.
Install the cross-arm (D).
4.
Unscrew the cap from the back gauge's
electrical socket (E, above and below) and
insert the gauge's electrical connector (F).
Secure the connector by turning the
knurled ring on the end of the connector
clockwise until it stops.
Connecting the back gauge's electrical connector.
CONNECTING POWER
IMPORTANT: Electrical wiring must be done
by a qualified electrician in conformance with
the prevailing electrical standards of your area.
Hazardous voltage. Will cause
serious injury or death. Turn
off supply electricity at your
facility’s circuit breaker before
making electrical connections to
the machine.
DANGER
C
A
B
A
C
E
B
D
F
E