DMX control
15
S e t t i n g t h e D M X a d d r e s s
Each unit on a DMX system must be allocated an address so that the DMX
controller can send separate commands to the unit. On the fog machine, the
DMX address is set using the bank of switches (“dip switches”) on the back
panel next to the DMX connectors. The switch settings for each possible DMX
address are given in the table below.
DIP-Switch Setting
0 = OFF
1 = ON
#9 0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
#8 0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
#7 0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
#6 0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
#1 #2 #3 #4 #5
0
0
0
0
0
32 64 96 128 160 192 224 256 288 320 352 384 416 448 480
1
0
0
0
0
1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481
0
1
0
0
0
2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482
1
1
0
0
0
3 35 67 99 131 163 195 227 259 291 323 355 387 419 451 483
0
0
1
0
0
4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484
1
0
1
0
0
5 37 69 101 133 165 197 229 261 293 325 357 389 421 453 485
0
1
1
0
0
6 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486
1
1
1
0
0
7 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487
0
0
0
1
0
8 40 72 104 136 168 200 232 264 296 328 360 392 424 456 488
1
0
0
1
0
9 41 73 105 137 169 201 233 265 297 329 361 393 425 457 489
0
1
0
1
0
10 42 74 106 138 170 202 234 266 298 330 362 394 426 458 490
1
1
0
1
0
11 43 75 107 139 171 203 235 267 299 331 363 395 427 459 491
0
0
1
1
0
12 44 76 108 140 172 204 236 268 300 332 364 396 428 460 492
1
0
1
1
0
13 45 77 109 141 173 205 237 269 301 333 365 397 429 461 493
0
1
1
1
0
14 46 78 110 142 174 206 238 270 302 334 366 398 430 462 494
1
1
1
1
0
15 47 79 111 143 175 207 239 271 303 335 367 399 431 463 495
0
0
0
0
1
16 48 80 112 144 176 208 240 272 304 336 368 400 432 464 496
1
0
0
0
1
17 49 81 113 145 177 209 241 273 305 337 369 401 433 465 497
0
1
0
0
1
18 50 82 114 146 178 210 242 274 306 338 370 402 434 466 498
1
1
0
0
1
19 51 83 115 147 179 211 243 275 307 339 371 403 435 467 499
0
0
1
0
1
20 52 84 116 148 180 212 244 276 308 340 372 404 436 468 500
1
0
1
0
1
21 53 85 117 149 181 213 245 277 309 341 373 405 437 469 501
0
1
1
0
1
22 54 86 118 150 182 214 246 278 310 342 374 406 438 470 502
1
1
1
0
1
23 55 87 119 151 183 215 247 279 311 343 375 407 439 471 503
0
0
0
1
1
24 56 88 120 152 184 216 248 280 312 344 376 408 440 472 504
1
0
0
1
1
25 57 89 121 153 185 217 249 281 313 345 377 409 441 473 505
0
1
0
1
1
26 58 90 122 154 186 218 250 282 314 346 378 410 442 474 506
1
1
0
1
1
27 59 91 123 155 187 219 251 283 315 347 379 411 443 475 507
0
0
1
1
1
28 60 92 124 156 188 220 252 284 316 348 380 412 444 476 508
1
0
1
1
1
29 61 93 125 157 189 221 253 285 317 349 381 413 445 477 509
0
1
1
1
1
30 62 94 126 158 190 222 254 286 318 350 382 414 446 478 510
1
1
1
1
1
31 63 95 127 159 191 223 255 287 319 351 383 415 447 479 511
Содержание JEM ZR44 Hi-MASS
Страница 1: ...user manual ZR44 HI MASS P N 35010032 D TM ...
Страница 23: ...23 ...
Страница 24: ...24 Notes Notes ...
Страница 25: ...25 ...
Страница 27: ...27 ...
Страница 28: ...Martin Professional A S Olof Palmes Allé 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin com ...