18
Basic service
Basic service
Before servicing the fog machine, read and observe all the precautions listed in
“Safety information” on page 4. Any service not described in this section must be
carried out by a Martin service technician.
C l e a n i n g
Excessive dust, fog fluid, and dirt build-up will degrade performance and cause
overheating and damage to the machine that is not covered by the product
warranty. To maintain adequate cooling, dust must be cleaned from the outer
casing and air vents of the machine periodically.
Isolate the machine from power and allow to cool completely before cleaning.
The fog output nozzle remains hot for up to 10 hours after use.
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
Clean fog fluid residues from the fog output of the machine using a
damp cloth.
Clean the outer casing with a damp cloth only.
F u s e r e p l a c e m e n t
The main fuse for the fog machine is located on the electronics board inside the
unit.
DANGER! Disconnect the power supply before removing any covers. Live parts
inside!
To replace the fuse, disconnect the power cord from the supply, unscrew the
screws holding the rear cover of the unit and remove the cover. The electronics
board is located at the back of the unit.
Remove the spent fuse and replace with one of exactly the same size and rating.
The fuse type is indicated below. Contact Martin Service if the fuse blows
repeatedly.
US Model = 20AT (slow-blow), 125 V
EU Model = 10AT (slow-blow), 250 V