SECTION 6 Preventive Maintenance Guide

0855904enb 4/05

 

m

®

6–11

To replace the web drive belt:

Feed the belt into position.

Remember to tighten the motor screws before checking the belt 
tension

Do not put an excessive amount of tension on the belt as this 
places undue strain on the motor bearings and will lead to 
premature wear

There should be approximately 15mm (.591”) of movement in the 
belt.

Содержание Cimjet RFID

Страница 1: ...Cimjet RFID Operation Service Manual m Operation Service Manual Cimjet RFID...

Страница 2: ......

Страница 3: ...ARKEM The foregoing warranty shall not apply to any custom work performed by MARKEM The foregoing warranty shall also not apply to defects or non conformance with MARKEM specifications which result fr...

Страница 4: ......

Страница 5: ...ow for reference When contacting MARKEM please give your Model Number Serial Number and Customer Account Number Model ____________ Serial Number_________________ Date Installed______________ Customer...

Страница 6: ......

Страница 7: ...12 2 7 Foreseen Use misuse 1 22 2 8 MARKEM Training Programs 1 22 2 9 Removal from Service 1 23 3 0 Overview 1 24 3 1 Components of Cimjet RFID 1 26 3 1 1 Dispenser 1 26 3 1 2 Applicator 1 26 3 2 Tag...

Страница 8: ...e User Guide 1 0 Restricted Access Mode User Guide 4 1 2 0 Entering Restricted Access Mode 4 1 3 0 Machine Init Initialization 4 2 3 1 Reset Params 4 2 4 0 Password 4 3 4 1 Password Configuration 4 4...

Страница 9: ...sor 6 7 6 2 Nip Home Sensor 6 7 6 3 Tag Gap Optic 6 8 7 0 Drive Belts 6 10 8 0 Maintaining the Compressed Air 6 12 Section 7 Technical Information 1 0 Power Configuration 7 1 1 1 Power Connector 7 1 1...

Страница 10: ...Feed Problems 8 8 6 1 Incorrect Tag Stopping Position 8 8 6 2 Erratic Tag Feeding 8 8 6 3 Inconsistent Tag Stopping Position 8 9 6 3 1 If the Tag Stops in the Correct Position 8 9 6 3 2 If the Tag St...

Страница 11: ...Cimjet RFID Operation Service Manual m SECTION 1 General Information...

Страница 12: ......

Страница 13: ...that radiate and or receive energy in the radio frequency spectrum to or from the tag bi directional a tag that can be read or written from either side capacity amount of bits or bytes that can be pr...

Страница 14: ...g expressed in bits or bytes per second read write many applications require that new data or revisions to data already in the tag be entered into the tag while it is still attached to its object tags...

Страница 15: ...g code plate and various other terms Although transponder is technically the most accurate the most common term and the one preferred by the Automatic Identification manufacturers is tag transponder s...

Страница 16: ...ons taken with the Cimjet RFID all connecting cables must be fully screened and the screen must have 360 degree contact with the metal connector and in turn the unit s case at both ends 2 2 Modificati...

Страница 17: ...llows Cimjet RFID Maximum current level 70A Duration 6ms Recommended cable protection is as follows MCB Miniature Circuit Breaker to IEC 947 2 EN 60947 2 and BS EN 60898 with a minimum instantaneous r...

Страница 18: ...ch as Robin Model KMP4120 Digital PSC LOOP Tester Connect tester to incoming mains supply to machine Check that the supply voltage is within specification and that the connections are correctly wired...

Страница 19: ...being earthed this therefore excludes any phase to phase connected supplies such as what might be available in some factories and or countries If either supply fuse located on the rear of the controll...

Страница 20: ...s used in areas where the floor may be wet or greasy 10 Be aware of the operating zone required by the Cimjet RFID when working with and near the machine Allow ample space beyond the applicator operat...

Страница 21: ...ties are detected in the laser beam generation internal protective devices must switch the laser beam off 15 Various safety and warning labels are placed on the Cimjet RFID see following pages WARNING...

Страница 22: ...on relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process unless specified in text Table 1 1 Safety Labe...

Страница 23: ...ine to highlight potential hazards to the operator Earth Part Number BO5264AA Earth labels are placed in strategic positions around the machine to highlight the machines earthing point Part Number 349...

Страница 24: ...er BO3286AA Supplier MARKEM Technologies Ltd Alexander Fleming Building Nottingham Science and Technology Park University Boulevard Nottingham NG7 2RF Composition Information on Ingredients Identifica...

Страница 25: ...degrease the skin First Aid Measures General Advice Use in well ventilated areas Inhalation Take patient to fresh air Do not move about Obtain medical advice Skin Contact Remove spillage with soft ti...

Страница 26: ...ter and isopropanol according to your local environmental regulations Otherwise absorb on an inert absorbent sand silica gel acid binder universal binder sawdust transfer to container and arrange remo...

Страница 27: ...and Body Protection Plastic apron sleeves boots dependent on amount handled Physical and Chemical Properties Isopropanol Wipes Form Of Liquid Color Colorless Odor Characteristic Melting Temperature 89...

Страница 28: ...s Odor Characteristic Melting Temperature 89o C Boiling Temperature 82o C Density g ml 0 78 Vapor Pressure 33 mmHg 20oC Density 2 07 Solubility in Water Miscible in all proportions Flash Point 12o C E...

Страница 29: ...may form explosive mixture with air Conditions to Avoid Keep away from heat and sources of ignition Materials to Avoid Oxidizing agents strong bases aldehydes ammonia chlorinated compounds amines orga...

Страница 30: ...iver injury may occur Chronic Toxicity Effects of excessive exposures may include liver toxicity Isopropanol Kits After Inhalation Irritation symptoms in the respiratory tract After Absorption Headach...

Страница 31: ...nvironmental hazard provided that the material is handled and disposed of with due care and attention Disposal Considerations Waste from Residues Unused Products Dispose of as special waste in complia...

Страница 32: ...sopropanol IMO Class 3 2 IMDG Page 3244 EmS 3 06 MFAG 305 Proper Shipping Name Isopropanol ICAO Class 3 UN ID No 1219 Proper Shipping Name Isopropanol Isopropanol Kits UN No 1219 IMDG Class II IMO 3 2...

Страница 33: ...90 492 EEC Symbol F Highly Flammable R Phrase s R11 Highly Flammable S Phrase s S2 Keep out of reach of children Keep container tightly closed in a cool well ventilated place S7 16 Keep away from sour...

Страница 34: ...dified without authorization Failing to observe hazard requirements in the manual and or on safety labels Combining or interfacing non MARKEM equipment with this system other than as intended Permitti...

Страница 35: ...ce These instructions also pertain to transporting or storing the applicator 1 Turn off the power to the Cimjet RFID 2 Disconnect the power cables from the system 3 Disconnect all other cables from th...

Страница 36: ...n refer to the Cimjet RFID Blow Applicator Manual 0855906 and the Cimjet RFID Tamp Applicator Manual 0855907 Left or right hand machine orientation to suit the application Easy loading of tags Network...

Страница 37: ...SECTION 1 General Information 0855904enb 4 05 m 1 25 Figure 1 1 Cimjet RFID Dispenser left hand option shown...

Страница 38: ...a variety of different mountable applicator modules 3 1 2 Applicator Several modular applicators are available to meet your different requirements The different applicators apply tags in different wa...

Страница 39: ...SECTION 1 General Information 0855904enb 4 05 m 1 27 Figure 1 2 Cimjet RFID Front Figure 1 3 Cimjet RFID Rear...

Страница 40: ...SECTION 1 General Information 1 28 m 0855804enb 4 05 Figure 1 4 Cimjet RFID Tag Optic...

Страница 41: ...as switched out of Auto Mode to Set Mode or there is a fault on the machine When the green light is on Cimjet RFID is awaiting a signal to start the Program Verify Reject Apply sequence When the blue...

Страница 42: ...SECTION 1 General Information 1 30 m 0855804enb 4 05 4 0 Dimensional Drawings in Millimeters Figure 1 5 Cimjet RFID Dispenser applicator not shown...

Страница 43: ...SECTION 1 General Information 0855904enb 4 05 m 1 31 Figure 1 6 Cimjet RFID Dispenser Stand...

Страница 44: ...SECTION 1 General Information 1 32 m 0855804enb 4 05...

Страница 45: ...Cimjet RFID Operation Service Manual m SECTION 2 Installation Guide...

Страница 46: ......

Страница 47: ...Compressed air a dry clean non lubricated air supply at 6 2 Bar 90psi Trigger signals depending on the application Sufficient space for installation and operation WARNING All applicator cylinders hav...

Страница 48: ...red The power supply is configured by Power connections to the toroidal transformer located at the rear of the machine Fitting of the corresponding fuse Details of this procedure are given in Section...

Страница 49: ...uncontaminated air which should not be lubricated 3 1 Air Regulator A filter regulator assembly is fitted to the base of the stand this is comprised of a manual isolation valve a water trap and press...

Страница 50: ...s standard so care should be taken to align the machine with the product transportation system Before final positioning the machine should be placed so that the applicator arm is square to the product...

Страница 51: ...Cimjet RFID Operation Service Manual m SECTION 3 Operating Guide...

Страница 52: ......

Страница 53: ...lars on the drive rollers to accommodate the width of the tag roll The tag roll should not rub on the collars Feed the backing web around the idler rollers between the optional post and the RF shield...

Страница 54: ...SECTION 3 Operating Guide 3 2 m 0855904enb 4 05 Figure 3 1 Webbing Diagram left hand option shown...

Страница 55: ...ation of the machine A warning sticker highlights the hazard Make sure that the power cable is connected and switch on the power at the rear of the machine During power up the user interface defaults...

Страница 56: ...ntrol panel user interface provides Machine setup and fault finding Error and Warning Messages 5 2 The Control Panel This drawing is a representation and is not to scale Four option soft keys Liquid C...

Страница 57: ...iew the next available parameter Press PREVIOUS to view the previous available parameter Saving and Discarding Changes The method of saving and discarding changes depends on the particular screen Gene...

Страница 58: ...ered by sensors or other inputs For further details refer to the Cimjet RFID Section 7 Technical Information Set Mode This mode provides a series of menus which allow you to a Run diagnostic tests b C...

Страница 59: ...cation is triggered by sensors or other inputs such as PLC control For details refer to the Cimjet RFID Section 7 Technical Information Figure 3 2 Auto Mode Menu Tree To select Auto Mode Press AUTO Th...

Страница 60: ...PARAMETERS TIME DATE MOVE PRINT CIM3 X X Y Y VIEW TIME DATE SET DATE SET TIME DIAGNOSTICS MANUAL TEST FEED SET TAG OPTIC DISP I O INPUTS OUTPUTS TIMINGS FEED FEED APPLY APPLY RIBBON FEED TOGGLE NEXT...

Страница 61: ...meters Set the time and date Cimjet RFID has a further level of restricted access menus which give access to other infrequently changed parameters For further information see Section 4 Restricted Acce...

Страница 62: ...perator to view the current status of the Cimjet RFID inputs and to test the various Cimjet RFID Outputs Full details can be found in Section 7 Technical Information 7 2 Set Tag Optic Cimjet RFID feed...

Страница 63: ...4 05 m 3 11 8 0 Parameters This option allows the operator to alter various operating parameters Time Date Enter the required date and time Time is entered in the 24 hour format TIME SET DATE PARAMET...

Страница 64: ...ation refer to Section 4 Restricted Access Mode User Guide Does not apply to Cimjet RFID Table 3 1 Parameter Description Apply Delay 25 This parameter allows the application of the tag onto the packag...

Страница 65: ...Cimjet RFID Operation Service Manual m SECTION 4 Restricted Access Mode User Guide...

Страница 66: ......

Страница 67: ...be changed by qualified MARKEM personnel or under close instruction from MARKEM 2 0 Entering Restricted Access Mode To enter Restricted Access Mode Select Set Mode Press and hold the ENTER and EXIT k...

Страница 68: ...is option resets all parameters to their default values The current selected applicator is not changed but the applicator parameters are set to the corresponding default values From the Machine Init m...

Страница 69: ...ssword has been typed The passwords for each access level are fixed The key sequences are given on the last page of this section This page may be removed if passwords are being used and if this manual...

Страница 70: ...s displayed Select CHANGE the following screen is displayed The NEXT and PREVIOUS keys are used to scroll through the four access levels To activate a specific button on any level press ENABLE with th...

Страница 71: ...right the first underscore activates the Restricted Setup buttons ENTER and EXIT pressed at the same time The next underscores are buttons 1 2 3 and 4 Access to the other soft keys and restricted acce...

Страница 72: ...3 3 1 Level 3 4 1 2 3 System 4 2 4 4 1 CAUTION If you have password protection to restricted access mode the SYSTEM user will automatically have access to this mode regardless of the SYSTEM password...

Страница 73: ...set into continuous operation for example to continuously cycle the Cimjet RFID unit See the main menu below Select CYCLE the following screen is displayed To start a cycle Press the required soft ke...

Страница 74: ...reen is displayed 7 0 Set Parameters This option allows various parameters to be viewed and changed From Restricted Setup menu Press SET PARAMETERS The Set Parameters screen is displayed The operator...

Страница 75: ...s configure the Communications port From the Set Parameters screen Press COMMS The first parameter is displayed Press CHANGE to select a different option See the following table for a full list of ava...

Страница 76: ...rotocol or desktop EMULATION protocol Comms Baud Range 2400 4800 9600 19200 38400 57600 115200 Default 19200 Host communications link baud rate Comms Link Range RS232 ETHERNET Default RS232 Host commu...

Страница 77: ...s These parameters configure the machine options available From the Set Parameters screen Press MACHINE OPTIONS The following screen is displayed This screen provides access to Applicator Parameters M...

Страница 78: ...Parameters These parameters configure various machine setup options From the Machine Option screen Press MACHINE CONFIG The first parameter is displayed The options can be accessed by using the NEXT a...

Страница 79: ...local memory Host PC Mode Cimjet RFID requests the required data from the Host PC Sensor Debounce Range 0 to 2000 Default 0 Delays the response to external sensors This is useful for example if the sh...

Страница 80: ...location Abort Range On Off Default Off An allocation set from CimControl can be stopped before it is completed Log Feed Data Range No To File Realtime Default No Status Output Range None Apply comple...

Страница 81: ...l Information Does not apply to Cimjet RFID Compatibility Mode Range On or Off Default On This determines if the CimComms Status Reset function is used or not Product Select Input Range On Off Default...

Страница 82: ...duration of the blow used to apply the tag This should be kept as short as possible while maintaining reliable tag application It is recommended that the Blow Time is on for the time it takes the tag...

Страница 83: ...ust remain at 0 for Cimjet RFID Ribbon Sensor Feed Speed Default 150 Feed Speed mm s is the time taken for the tag to pass the nip roll Optic Position Default NEW Sensor location prevents tag gap from...

Страница 84: ...User Guide 4 18 m 0855904enb 4 05 Does not apply to Cimjet RFID Feeder Hand Range LEFT RIGHT Default LEFT Defines on which side of the feeder the image is aligned Table 4 4 Restricted Setup Set Parame...

Страница 85: ...Cimjet RFID Operation Service Manual m SECTION 5 Operating Modes...

Страница 86: ......

Страница 87: ...rformed using a serial communications link Three factors determine the position of the tag on the pack The position of the applicator relative to the conveyor The position of the sensor The setting of...

Страница 88: ...s completed the air assist jets hold the tag to the applicator The applicator waits for the apply delay timer to elapse then activates the apply mechanism Note No Apply sensor is used 2 2 On Demand Mo...

Страница 89: ...X23 it is recommended that a single multi core cable be run in conduit to a junction box The junction box can be mounted at a convenient position and individual cables run to the sensors and conveyor...

Страница 90: ...the Feed sensor is used and the tag is applied automatically after the Apply delay timer has elapsed The Feed sensor should be positioned far enough away from the Cimjet applicator prior to the tag ap...

Страница 91: ...tag on the pack The product s pitch spacing frequency and speed determine the position of the Feed sensor The sensor must be mounted far enough away from the Cimjet applicator prior to the tag applic...

Страница 92: ...4 05 5 0 Fitting the Sensors When the optimum position of the sensors is determined mount the sensor firmly in place 6 0 Apply Delay The Apply Delay can either be set from the Set Mode Parameter scree...

Страница 93: ...Cimjet RFID Operation Service Manual m SECTION 6 Preventive Maintenance Guide...

Страница 94: ......

Страница 95: ...ction which should include Check all guards to ensure they are correctly fitted using all required fasteners Check that movement is smooth and that slides and cylinders are not damaged Check for wear...

Страница 96: ...to the machine and its delicate components Cleaning agents which will damage rubber or plastic MUST NOT be used If in doubt consult MARKEM It is recommended that the rollers be cleaned regularly every...

Страница 97: ...b When the tag height size is altered check the following After webbing up the machine use the Engineer Mode to set the tag optic sensor Check that the new tag size gap does not stop in the Gap sensor...

Страница 98: ...band should be replaced If the brake is not operating correctly a heavy supply reel will tend to overrun and introduce slack into the tag supply path To replace the brake band Power off the machine T...

Страница 99: ...tch felt pads need replacement between intervals of six months to one year do the following refer to Figure 6 2 Remove the plastic end cap 1 Use a box spanner deep socket nut driver 10mm A F to remove...

Страница 100: ...spanner deep socket nut driver 10mm AF on the nut 2 to adjust the torque turn the nut clockwise to increase torque To set the torque first turn the nut counterclockwise until the clutch slips very ea...

Страница 101: ...el type inductive sensor is used to sense the position of the rear of the pivoted nip arm To replace this sensor Turn off all power to the machine Turn off and lock off the air supply to the machine R...

Страница 102: ...8 Stepper motor 8 steps mm When the Cimjet RFID feeds datum labels the processor will record a constant voltage level for 800 100mm 3 94 x 8 steps of the stepper motor and then record a rise in the vo...

Страница 103: ...ugh the sensor Note the voltage when the sensor is looking through the gap just webbing material versus when it is looking through the label on the webbing material Check that the threshold voltage is...

Страница 104: ...stration shows the position of the stepper motor used and the path of the timing belt To remove the web drive belt Loosen all four screws on the stepper motor Remove the belt tension by rotating the e...

Страница 105: ...ed the belt into position Remember to tighten the motor screws before checking the belt tension Do not put an excessive amount of tension on the belt as this places undue strain on the motor bearings...

Страница 106: ...e main pressure regulator and this will require draining at regular intervals prior to machine use Carry out the following procedures Check the water level in the water trap Place a suitable container...

Страница 107: ...Cimjet RFID Operation Service Manual m SECTION 7 Technical Information...

Страница 108: ......

Страница 109: ...the necessary power connections and fuse fitted to suit customer requirements If the requirements change the Cimjet RFID can be quickly reconfigured by modifying the power connections 1 1 Power Conne...

Страница 110: ...ocated at the rear of the machine The connection arrangement depends on the supply voltage The machine can be configured for 115V or 230V by adding or removing the wire link provided Connect the live...

Страница 111: ...r Voltage Adjustment X36 SW1 LD 8 X18 FR3 SW2 LK3 TP10 TP6 FR1 TP3 X25 TP20 X19 LD 9 TP 32 U12 TP7 TP27 X38 X27 X9 FR7 LK17 LK8 LD 15 TP5 TP34 TP 12 LD 4 LD21 RV2 X21 TP25 X7 LD 5 HI ROM FR4 LD 10 LK9...

Страница 112: ...X2 X3 Head Lift Solenoid X4 Totalizing Counter 1 24VSOL 2 Output X5 Gap Optic Drive 1 Drive 2 0VA 3 5VA 4 Sense X8 Beacon Outputs 1 Ready N O 2 Warning N O 3 Fault N C 4 0VP X9 Output 5 N C 2 way Mole...

Страница 113: ...ctor 1 Signal 2 0VP X19 Reject Mechanism Solenoid Output 9 N O 2 way Molex Connector 1 Signal 2 0VP X20 Output 6 N O 2 way Molex Connector 1 Signal 2 0VP X22 Head Nip Open 3 way Molex Connector 1 24VS...

Страница 114: ...ay D type Connector X29 Web Motor Drive 4 way Molex X31 Internal Microprocessor Pins 1 36 X32 Internal Microprocessor Pins 37 72 X33 Internal Microprocessor Pins 73 108 X34 Internal Microprocessor Pin...

Страница 115: ...Ds Table 7 2 Input LEDs Input LED Function Main Processor Board LD1 Feed and Apply Input LD2 Spare External Input 1 LD3 E stop Monitor LD4 Guards Monitor LD5 Applicator Input 3 Spare External Input 2...

Страница 116: ...4enb 4 05 Table 7 3 Output LEDs Output LED Function Main Processor Board LD10 Fault LD11 Warning LD12 Reject LD13 Busy LD14 Applicator Specific LD15 Applicator Specific LD16 Applicator Specific LD17 A...

Страница 117: ...or Link positions 1 2 3 4 24V Link positions 2 3 4 5 Volt free operation Default LK4 Ready Output 5 way link LK5 Fault Output 5 way link LK6 Warning Output 5 way link LK7 Reject Output 5 way link LK8...

Страница 118: ...SECTION 7 Technical Information 7 10 m 0855904enb 4 05 LK17 Bootstrap link Program upgrade via RS232 A Default B Bootstrap enabled Table 7 4 Processor Board Links Link Number Function...

Страница 119: ...ic supply TP3 Reject Mechanism Solenoid PWM Switched Output TP4 Reject Mechanism Solenoid On Off Switched Output TP5 Counter Out Output for Optional Hardware TP7 Tag Gap Analogue Sensor Output TP8 Tag...

Страница 120: ...Comms Port RS232 Input Data TP26 VM Motor Voltage Nominally 42V Unregulated TP27 0VM Motor Voltage Ground TP28 0VI Isolated 5V Supply Ground TP29 5VI Isolated and Regulated 5V Supply TP35 SYSCLK 20MH...

Страница 121: ...13 2 5 Fuses Table 7 6 Fuses Fuse Function FR2 24V I O and Beacon Supplies 1 35A FR3 24V Solenoid Supply 0 75A FR4 24V SPI Supply 0 75A FR5 24V Sensors Supply 0 75A FR6 Motor Reject Supply 4A FR7 5V...

Страница 122: ...These options are as follows On board Internal Flash ROM External Pluggable Flash ROM External PROMs These various options require that the appropriate links are set See previous pages in this section...

Страница 123: ...haracteristic of standard tags but may not be appropriate for all applications The voltage settings can be viewed on the Engineer Mode Diagnostics Screen and the appropriate adjustments can be made to...

Страница 124: ...are provided on the rear of the Cimjet RFID CAUTION It is essential that the connector dust covers pro vided with the machine are fitted to all unused connectors to protect against dust and prevent p...

Страница 125: ...igure 7 4 shows suitable RS232 cables for connecting your PC to the Cimjet RFID For RS485 wiring details please refer to Section 10 Parts Illustrations and Schematics Figure 7 4 PC to Cimjet RFID RS23...

Страница 126: ...perate with PNP sensors or volt free contacts If external voltage is used it must not exceed 30VDC Where volt free contact is used the contact should be wired between the input pin and one of the 24V...

Страница 127: ...supply A number of additional connections are provided Motor Safety When LK9 on the mother board is removed the motor safety connections on X12 must be connected The relay or output used must be capa...

Страница 128: ...t 24V LK5 4 Fault C 0V 5 Fault N C Fault 24V 6 Warning N O Warning 24V LK6 7 Warning C 0V 8 Warning N C Warning 24V 9 Reject N O Reject 24V LK7 10 Reject C 0V 11 Busy N O SPOUT 24V LK8 12 Busy C 0V 13...

Страница 129: ...y cycle the status output can then be reset by one of the user options in the restricted access menu machine configure parameters 24V Output N O or N C contacts switched by the Cimjet RFID Connections...

Страница 130: ...nt means one of which is by the Status Reset Input This input is normally switched by the external control system Note This is only available if the optional serial laser board is fitted Connections o...

Страница 131: ...activate the machine outputs for testing purposes These functions can be accessed from the Engineer Mode screen under Diagnostics Select ENGINEER MODE Select DIAGNOSTICS The I O screen can be extremel...

Страница 132: ...their status on the Engineer Mode Diagnostic screen Select Disp I O from the Engineer Mode Diagnostic screen The inputs screen is displayed The status of Applicator Inputs depends on the type of appl...

Страница 133: ...to start the apply sequence Status On Off Low Web Indicates the condition of the Low Paper warning sensor Status On Off Spare Input Applicator specific Spare Input Applicator specific Nip Closed Indi...

Страница 134: ...n 2 Database Size Displays the size of database fitted such as 512K Software Version Displays the current release of firmware being used in the machine such as P2850 11 07 01 Board Revision Displays t...

Страница 135: ...gnostic screen To select the Outputs screen Press the soft key next to INPUTS The Outputs screen is displayed The condition of the outputs can be changed by using the TOGGLE soft key DISP I O TIMINGS...

Страница 136: ...machine Pin 23 TXD2 RS232 Optional Pin 24 RXD2 RS232 Optional Pin 25 RS232 Ground Table 7 11 Diagnostic Screen Outputs Output Description Ready An input for the conveyor PLC or for a Beacon lamp Warn...

Страница 137: ...d of a manual isolation valve a water trap pressure regulator and dump valve The air supply is via a 6mm or 8mm flexible pipe 9 2 Compressed Air Requirements WARNING Do not adjust the regulator pressu...

Страница 138: ...Regulator Unit A 6mm 236 push fitting is provided to accept flexible pipe The supply should be at 6 2 Bar 90psi It should also be dry clean and not lubricated The regulator unit provides a regulated...

Страница 139: ...e air regulator which is mounted inside the dispenser cover next to the solenoid valve that operates it Figure 7 6 Air Regulator and Solenoid Valve for Tag Reject Mechanism The air pressure for the Ta...

Страница 140: ...SECTION 7 Technical Information 7 32 m 0855904enb 4 05...

Страница 141: ...Cimjet RFID Operation Service Manual m SECTION 8 Troubleshooting Guide...

Страница 142: ......

Страница 143: ...lear the fault For example When Cimjet RFID is in error the machine ready output is opened and the fault output closes The following tables list the errors that can occur together with the remedial ac...

Страница 144: ...one of the following messages will be displayed Table 8 1 Power up Error Messages Message Indication Action Parameters Lost Setup parameters are corrupt Check all setup parameters to ensure correct o...

Страница 145: ...The tag gap sensor is not detecting tags If tags are loaded check that the tags are passing through the tag gap optic sensor If tags are present reset the tag gap optic from the Engineer Mode Paramete...

Страница 146: ...er Description Action 01 NO WEB CHECK TAG SENSOR THEN PRESS AUTO 03 NIP OPEN CHECK NIP THEN PRESS AUTO 04 CYLINDER FAILED TO RETURN HOME PRESS AUTO 05 MISSING TAG CHECK TAG SUPPLY THEN PRESS AUTO 06 M...

Страница 147: ...ILED TO RETURN HOME PRESS AUTO 22 CYLINDER 1 TIMED OUT PRESS AUTO 23 CYLINDER 2 TIMED OUT PRESS AUTO 24 PAD ROTATE TIMEOUT PRESS AUTO 25 APPLICATOR OBSTRUCTED IN CYCLE PRESS AUTO 26 NO REJECT TAG AVAI...

Страница 148: ...CTION 8 Troubleshooting Guide 8 6 m 0855904enb 4 05 35 PLC MODE CYCLE 2 DETECTED NO CYCLE 2 DEFINED PRESS AUTO 36 HOST PRINT CYCLE 2 DETECTED NO CYCLE 2 DEFINED PRESS AUTO Table 8 3 Other Error Messag...

Страница 149: ...ns parameters for the Cimjet RFID and the host computer match These are Communications Speed Baud Rate This is set in Restricted Access Mode Data Bits Stop Bits and Parity Cimjet RFID always uses 8 da...

Страница 150: ...incorrect after datum tags have been fed and the stop position is consistent check the following FEED ADJUST parameter BACKFEED parameter should always be set to 0 for Cimjet RFID See the print parame...

Страница 151: ...k that the nip roller is positioned in the center of the tag Check that the drive roller is clean Check that the dancer arm is operating 6 3 2 If the Tag Stops in an Inconsistent Position If the tag s...

Страница 152: ...or voltage test point Ensure the external motor control link is in position LK9 on the main PCB 8 0 Motor Stalling Tag feed problems could also be caused by the motor stalling The following problems m...

Страница 153: ...Cimjet RFID Operation Service Manual m SECTION 9 Recommended Spares...

Страница 154: ......

Страница 155: ...neral Spares Kits 1 1 Preventive Maintenance Spares Kits Table 9 1 Roller Cleaning Part No Qty Description 5824648 100 Cleaning Pads Table 9 2 Maintenance Parts 100mm 3 94 Part No Qty Description 3311...

Страница 156: ...1BB 1 Operator Panel Assembly 35146BA 1 LCD Display Assembly 5564342 1 Solenoid Assembly Table 9 4 Left hand Change Parts Part No Description B05281AA 452 906 Blank Insert B03636AA 453 886 Screwlock 8...

Страница 157: ...Cimjet RFID Operation Service Manual m Section 10 Parts Illustrations and Electrical Schematics...

Страница 158: ......

Отзывы: