8516 Hybrid NVR with RAID Installation Guide
28
Unit Setup
Rack-Mounting
Rack-mount the docking station in a standard 19-inch rack (RR model only).
To rack-mount the docking station
1
Position the docking station in the appropriate position.
2
Attach the docking station to the rack using four screws. For details about recommended
screws, consult the documentation accompanying the rack.
WARNING:
Airspace or airflow around the unit and docking station must provide ambient air of
less than 104° Fahrenheit (40° Celsius) when measured above and below the unit
and docking station.
Wall-Mounting
Wall-mount the docking station or the recorder unit using the brackets provided in the wall-
mounting kit. The wall-mounting kit is not included with the recorder: it must be purchased
separately.
WARNING:
The unit must be mounted with the cooling fans and the drip trays at the bottom.
Ensure the location where you wall-mount the unit can fully support the unit’s
weight. For information about the weight, see “Specifications” on page 12. To
ensure the unit does not exceed the recommended operating temperature, the unit
must be wall-mounted in a location where it is unobstructed on all sides.
Items Required to Wall-Mount
The following items are required to wall-mount:
•
Mounting screws
— pan head, sheet metal screw, #14 x 1.5 inch, steel, six (6) screws required
•
Drywall anchors
— four (4) anchors required, to use with #14 mounting screws
Rack
Screws