Part Number 80-1505-3 6/11
93
G. Remove the water pump.
•
Note position of water pump outlet, and then
disconnect vinyl hose from the pump outlet.
•
Rotate the thumbscrew that secures the pump to
the bulkhead 1/4 turn clockwise.
•
Rotate the water pump assembly 1/4 turn
counterclockwise.
•
Lower the pump assembly into the evaporator
compartment.
•
Disconnect the water pump power cord.
•
Remove water pump assembly from ice
machine.Do not soak the water pump motor in
cleaner or sanitizer solution
H. Remove the bin thermostat probe
•
Loosen the 2 screws that holds the probe in place.
The probe can easily be cleaned at this point
without complete removal.
NOTE: Proceed to page 101, Step 7.
Содержание SD0672C
Страница 2: ......
Страница 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Страница 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Страница 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Страница 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Страница 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Страница 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Страница 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Страница 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Страница 232: ...232 Part Number 80 1505 3 6 11 ...
Страница 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Страница 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Страница 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 297: ......