120
Part N
u
mber 80-
1505-
3 6/11
Quad Evaporator Energized Parts Chart
Ice Making
Sequence of
Operation
Water
Pump
Harvest
Valve (s)
Air Pumps
Water Inlet
Valve
Water
Dump
Valve
Liquid Line
Solenoid
Valve
Refrigeration
Compressor &
Condenser Fan
Motor
Length of
Time
Start-Up - Initial or After
Auto Shut Off
1. Water Purge
On
Off
Off
Off
On
Off
Off
45 Seconds
2. Refrigeration
System Start-up
Off
Off
Off
On
Off
On
On
5 Seconds
Freeze Sequence
3. Pre chill
Off
Off
Off
On
Cycles Off
then
On/Off one
more time
Off
On
On
30 Seconds
4. Freeze
On
Off
Off
Off
On
On
Until 10 sec. water
contact with ice
thickness probe
Harvest Sequence
5. Water Purge
On
On
On
Off
On
On
On
45 Seconds
Содержание SD0672C
Страница 2: ......
Страница 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Страница 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Страница 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Страница 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Страница 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Страница 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Страница 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Страница 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Страница 232: ...232 Part Number 80 1505 3 6 11 ...
Страница 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Страница 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Страница 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 297: ......