122
Part Number 80-1505-3 6/11
Safety Timers
The control board has the following non-adjustable safety
timers:
•
The ice machine is locked into the freeze cycle for 6
minutes before a harvest cycle can be initiated.
•
The maximum freeze time is 60 minutes at which time
the control board automatically initiates a harvest
sequence (steps 5 & 6).
•
The maximum harvest time is 3.5 minutes at which time
the control board automatically ends the harvest cycle.
When the bin switch is closed a freeze sequence initiates
(steps 3 & 4). When the bin switch is open an automatic
shutoff sequence initiates.
•
The maximum water fill is 6 minutes.
Water Assist Harvest Feature
Twin & Quad Evaporators Only:
Typical duration of a Harvest sequence is less than 2.5
minutes. When the Harvest sequence time reaches 4
minutes, the following occurs:
4 minutes into a Harvest sequence: The water fill valve will
energize to fill the trough with water.
5 minutes into a Harvest sequence: The water pump will
energize and flow water over the evaporators.
The water fill valve and water pump remain on until all bin
switches have been activated, or until the 7-minute Harvest
sequence time limit is reached.
Warm Water Rinse Cycle
Single & Twin Evaporators Only:
Closing the back of the evaporator allows ice to build up on
the rear of the evaporator and the plastic evaporator frame
parts. After 200 freeze/harvest cycles have been complete
the control board will initiate a warm water rinse.
After the 200th harvest cycle ends:
•
The Clean and Harvest LED’s energize to indicate the ice
machine is in a warm water rinse.
•
The compressor and harvest valve remain energized.
•
The water pump energizes.
•
The water inlet valve energizes until water contacts the
water level probe.
•
The compressor and harvest valve warm the water for 5
minutes, then de-energize.
•
The water pump remains energized for an additional 5
minutes (10 minute total on time) then de-energizes.
The warm water rinse cycle can be terminated by moving the
toggle switch to the OFF position, then back to ICE.
Содержание SD0672C
Страница 2: ......
Страница 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Страница 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Страница 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Страница 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Страница 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Страница 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Страница 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Страница 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Страница 232: ...232 Part Number 80 1505 3 6 11 ...
Страница 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Страница 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Страница 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 297: ......