Analyzing Freeze Cycle Suction Line
Temperature
Suction line temperature cannot diagnose an ice
machine. However, comparing this temperature during
the freeze cycle, along with using Manitowoc’s
Symptom #2 - Refrigeration System Operational
Analysis Table, can help diagnose an ice machine
malfunction.
The actual temperature of the suction line varies by
model, and will change throughout the freeze cycle.
This makes documenting the “normal” suction line
temperature difficult. The key to the diagnosis is
observing the compressor suction line temperature
during the last three minutes of the freeze cycle.
1. Use a quality temperature meter, capable of
taking temperature readings on curved copper
lines.
2. Attach the temperature meter thermocouple to the
copper suction line within 6” of the shut-off valves.
3. Monitor the suction line temperature during the
last three minutes of the freeze cycle and record
the low event.
4. Use this with other information gathered on the
Refrigeration Component Analysis Chart to
determine the ice machine malfunction.
5. Verify refrigerant amount is correct by weight
when recovering refrigerant and replacing a TXV.
Grossly overcharged QuietQube® ice machine in
ambient temperatures below 70°F will have a
suction line temperature below 10°F.
Important
Do not simply insert the sensing device under the
insulation. It must be attached to and reading the
actual temperature of the copper line.
Содержание SD0672C
Страница 2: ......
Страница 65: ...Part Number 80 1505 3 6 11 65 This Page Intentionally Left Blank ...
Страница 66: ...66 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 79: ...Part Number 80 1505 3 6 11 79 A B C D ...
Страница 81: ...Part Number 80 1505 3 6 11 81 A B C D E I ...
Страница 90: ...90 Part Number 80 1505 3 6 11 A B C D E F G ...
Страница 94: ...94 Part Number 80 1505 3 6 11 A B C E F D G H ...
Страница 97: ...Part Number 80 1505 3 6 11 97 A B C D F G E ...
Страница 100: ...100 Part Number 80 1505 3 6 11 A B C D E F G H ...
Страница 174: ...174 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 198: ...198 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 229: ...Part Number 80 1505 3 6 11 229 SV1406 USING PINCH OFF TOOL ...
Страница 232: ...232 Part Number 80 1505 3 6 11 ...
Страница 238: ...238 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 276: ...276 Part Number 80 1505 3 6 11 S3070C 230V 50HZ 1PH ...
Страница 283: ...Part Number 80 1505 3 6 11 283 CVD3085 380V 50HZ 3PH ...
Страница 296: ...296 Part Number 80 1505 3 6 11 This Page Intentionally Left Blank ...
Страница 297: ......