Grove
Published 01-14-2021 Control # 707-01
3-17
TMS9000-2 SERVICE MANUAL
ELECTRICAL SYSTEM
3
Installation
1.
Place the batteries in the battery compartment. Refer to
(Figure 3-24).
2.
Install the hold down brackets. Secure the brackets to
the bracket hold down rods with nuts and washers.
3.
Make sure the battery disconnect switch is in the
disconnect position and all key switches are in the “OFF”
position.
4.
Connect cables to the battery terminals starting with the
positive terminals.
5.
Close the battery box cover.
6.
Install the ECM power fuse.
7.
Turn the battery disconnect switch to ON.
8.
Verify replacement batteries work by starting crane’s
engine and operating various crane components.
1
2
3
9284
4
4
5
FIGURE 3-24
9284-1
Item
Description
Item
Description
1
Battery Disconnect Switch
4
Negative Cables
2
Battery Hold Down
5
Batteries (4)
3
Positive Cables
Fo
r
Reference
Only