2-52
Published 01-14-2021 Control # 707-01
HYDRAULIC SYSTEM
TMS9000-2 SERVICE MANUAL
5.
Stop engine and remove the diagnostic coupler.
6.
Assure the piston pump “cut-off” max setting is correct.
Loosen the jam nut on the cut-off pressure adjusting
screw. See (Figure 2-14) and turn it “in” until it softly
seats or bottoms out. Then back the adjusting screw
“out” ½ turn and lock in place with the jam nut. Perform
this step on both pumps.
B. Procedure for Checking/Setting the Pilot
Supply Pressure
1.
With the engine off, install pressure check diagnostic
quick disconnect (Parker PD240) with gauge onto test
FIGURE 2-31
Differential pressure
adjustment screw
Piston pump #1
9266
Cut-off pressure
adjustment screw
Piston pump #2
Fo
r
Reference
Only