50
Part Number 80-1479-3 10/10
ICE MACHINE WILL NOT HARVEST
SCR Timer
1. Check for line voltage at terminals 1 & 2 and C & 2.
If line voltage is not present refer to toggle switch
diagnostics.
2. Check for line voltage at 2 & 6.
No line voltage
Refer to evaporator thermostat diagnostics.
Evaporator temperature must be below setpoint.
Line Voltage
Momentarily disconnect then reconnect power to #6.
3. Wait 11 minutes.
Ice machine cycles into harvest - Refer to
evaporator thermostat diagnostics.The evaporator
thermostat must open the trigger contact (#6) to
reset the freeze cycle time. If power is not broken at
# 6 the ice machine will remain in the freeze cycle
and never initiate a harvest cycle.
Ice machine remains in freeze - Replace timer.
2
C
NC
NO
1
6
5
4
3
2
5
15
13
11
9
7
1
6
Содержание EC18
Страница 2: ......
Страница 6: ...This Page Intentionally Left Blank ...
Страница 12: ...This Page Intentionally Left Blank ...
Страница 14: ... 2 This Page Intentionally Left Blank ...
Страница 24: ...12 Part Number 80 1479 3 10 10 Evaporator Ice Chute Spray Bar Spray Nozzles Toggle Switch ...
Страница 42: ...30 Part Number 80 1479 3 10 10 This Page Intentionally Left Blank ...
Страница 74: ...62 Part Number 80 1479 3 10 10 This Page Intentionally Left Blank ...
Страница 75: ...Part Number 80 1479 3 10 10 63 ...
Страница 100: ... 87 This Page Intentionally Left Blank ...
Страница 101: ... 88 This Page Intentionally Left Blank ...
Страница 175: ... 162 This Page Intentionally Left Blank ...
Страница 181: ... 168 ...
Страница 182: ......
Страница 183: ......