–99–
EC20 (WITHOUT TIMER) SELF-CONTAINED AIR-COOLED — STANDARD CUBE
NOTE:
These characteristics may vary depending on operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Continued on next page …
Air Temp.
Entering
Condenser
°C
Freeze Time
Harvest
Time
Times
in
minutes.
Water Temperature °C
10
15
20
25
30
35
40
10
19.1-21.4
3.5 min.
15
19.7-22.1
19.8-22.2
20
21.2-23.8
21.4-23.9
21.5-24.1
21.7-24.3
21.4-23.9
25
22.8-25.5
24.0-26.8
23.3-26.0
23.4-26.2
23.6-26.4
30
24.7-27.6
24.9-27.8
25.1-28.1
25.3-28.3
25.7-28.7
25.9-29.0
26.1-29.2
35
27.7-30.9
27.7-30.9
27.9-31.1
28.1-31.4
28.6-31.9
40
30.7-34.3
31.0-34.6
31.3-34.9
45
34.1-38.0
34.6-38.4
34.8-38.8