–122–
EC40 SELF-CONTAINED WATER-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Condenser Water
Consumption
32 Air Temperature Around Ice Machine
Water Temperature °C
15
21
32
Gal/24 Hours
478
744
2283
Water regulating valve set to maintain 9 bar discharge pressure.
Water Temperature
Entering Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
Set water regulating valve to 9 bar 5 minutes into freeze cycle.
All pressures are in bar.
Suction pressure drops gradually throughout the freeze cycle.
10
10.34-8.62
1.79-.28
3.10-5.87
2.07-3.45
20
11.03-8.62
1.79-.34
3.10-7.24
2.07-4.82
25
11.03-8.62
1.79-.41
3.10-7.24
2.07-4.82
32
11.03-8.62
2.00-.41
3.10-7.24
2.07-4.82
43
11.72-8.62
2.00-.48
3.45-8.62
2.07-5.87
Содержание EC18
Страница 2: ......
Страница 6: ...This Page Intentionally Left Blank ...
Страница 12: ...This Page Intentionally Left Blank ...
Страница 14: ... 2 This Page Intentionally Left Blank ...
Страница 24: ...12 Part Number 80 1479 3 10 10 Evaporator Ice Chute Spray Bar Spray Nozzles Toggle Switch ...
Страница 42: ...30 Part Number 80 1479 3 10 10 This Page Intentionally Left Blank ...
Страница 74: ...62 Part Number 80 1479 3 10 10 This Page Intentionally Left Blank ...
Страница 75: ...Part Number 80 1479 3 10 10 63 ...
Страница 100: ... 87 This Page Intentionally Left Blank ...
Страница 101: ... 88 This Page Intentionally Left Blank ...
Страница 175: ... 162 This Page Intentionally Left Blank ...
Страница 181: ... 168 ...
Страница 182: ......
Страница 183: ......