44
Part Number 80-1479-3 10/10
ICE MACHINE PREMATURELY HARVESTS
Mechanical Timer
1. Evaporator thermostat correctly set?
2. Timer micro switch relays in N.O. position?
(wires #3 & #6-16 open - wires #33 & #4-5 closed)
3. Evaporator thermostat terminals #2 & #3
(Common) open?
4. Timer motor winding closed?
5. Timer functions mechanically?
6. Timer cam changes relay micro switch position?
(relay 1 - wires #3 & #6-16 must close.
3
2
1
4
Содержание EC18