background image

 

M&V S.r.l. 

Via L. Guerra, 9 

80040 Cercola (NA) 

Ph./Fax +39 0815552428 

e-mail: 

[email protected]

 

© M&V S.r.l. 

 

 

vesuvius userguide10 June 2015.doc 

 

 

 

 

Page 3 of 24 

Information Technology Solutions 

V

ESUVIUS OWNERS MANUAL

 

Introduction 

 

Congratulations on the purchase of the worlds first 
prosumer, computer controlled pressure profiling 
Vesuvius using and E61 group. This advanced 
espresso machine uses true pressure profiling via 
the FG304 gear pump and speed controllable 
brushless motor. Currently there is no other 
prosumer machine available with these functions, so 
some of the techniques for using the Vesuvius are 
slightly different to other espresso machines 
 
The pump and pressure settings can be set up in 
many ways, so many, that the owners manual is just 
a starting point for your journey. 
 

Paolo Cortese (Designer, Director) 
Antonio Nurri (Director & Head of marketing) 

 

Vesuvius Supplied Items.  

  The Vesuvius Espresso machine 

  Wooden Accessory Case 

  2 portafilter handles (with double and single 

baskets and blind filter basket 

  Small Accessories Bag (Various useful 

maintenance items) 

  4 Metal Feet, 2 small (front), 2 large (Rear) 

  Drain hose 

  Water supply hose 

  Appropriate certifications, This manual and 

any additional notes  

Product Safety Notice  

This manual is an integral and essential part of the 
product and is to be delivered to the user. Carefully 
read all warnings as they provide important 
information required to install, use and maintain the 
Vesuvius 

Inspection and unpacking 

After having removed the packaging, make certain 
that the Vesuvius is not damaged in any way. If you 
have any doubts, do not use the Vesuvius and 
contact a professionally qualified person or your 
dealer. Always keep all packaging including any 
plastic bags, internal packing screws, and rubber 
transit feet etc.). All packing materials should be 

kept out of reach of children and disposed of 
responsibly in accordance with your countries 
recycling and disposal arrangements. 
 

General Installation precautions 

Before switching on the Vesuvius make certain 
that the rating indicated on the label matches the 
available power supply. The serial number and 
rating label is located behind the drip tray.  
 
Installation should be in line with the standards and 
laws within the of the country where it is being 
installed, following any manufacturer's specific 
instructions and checks. 
 
Properly skilled personnel should install when 
connected to the rising main. The manufacturer 
cannot be held responsible for any damages 
incurred if the system is not electrically grounded, or 
by water leaks when connected to the rising main.  
 
For electrical safety, this machine requires a ground 
or earth. If in any doubt contact a technically certified 
electrician who must check that the electrical outlet 
used has adequate capacity for the current draw of 
the machine and that it is properly grounded.  
 
The use of extension leads, adaptors or any other 
equipment between the Vesuvius and the mains 
supply socket is not recommended. If for any reason 
this type of equipment must be used, you should 
consult a qualified electrician

Different countries 

have different regulations for plumbed in 
machines. Before plumbing in the Vesuvius, you 
should consult with a qualified plumber and/or 
ensure all in county regulations are followed. 

Always ensure the portafilter is locked in 
correctly 

Failure to do this can result in the portafilter coming 
undone, with the risk of scalding or breaking any 
cups below. Please lock to the 6:00 position or 
further for safe operation 

Содержание Vesuvius

Страница 1: ...ia L Guerra 9 80040 Cercola NA Ph Fax 39 0815552428 e mail info mevsrl net M V S r l vesuvius userguide10 June 2015 doc Page 1 of 24 Information Technology Solutions VESUVIUS OWNERS MANUAL VESUVIUS OW...

Страница 2: ...lay programming functions 9 Main Vesuvius Screens 9 Turning the Steam Service boiler on or off 10 Main Menu Screen 11 Eco Mode Explained 12 Eco Mode Explained cont 13 The profile screen 15 Programming...

Страница 3: ...r your dealer Always keep all packaging including any plastic bags internal packing screws and rubber transit feet etc All packing materials should be kept out of reach of children and disposed of res...

Страница 4: ...cedure should be used 1 All 4 screws securing the lid should be removed There are 1 on each side shown by the arrows 4 in total Note they are NOT on the top 2 The sides of the crate are secured by 4 m...

Страница 5: ...when plumbing in Use the flexible hose provided with the machine connect it to a connection hose 3 8 male with a shut off valve The use of a water softer or filtration system is advised The drip tray...

Страница 6: ...the firmware has loaded turn the machine on from the front panel Within a few moments the pump may start to run 3 Lift the brew lever always do this 4 the water level in the tank should fall and withi...

Страница 7: ...Height adjustable feet Cup Warmer rack Dot matrix display Touch sensitive Brew and steam boiler LEDs lights when heating Water wand ball joint mounted no burn Toggle Valve to draw water Drip tray remo...

Страница 8: ...uminated on off rocker switch Side Panel access toggle Removable panel access heating element removal service boiler drain plug Plumbed Tanked operation rocker switch Illuminated when set for plumbed...

Страница 9: ...oiler temperature and pressure The next Zone shows what pressure profile is being used and this is a sideways scrolling display The third zone has a tank water level indicator which actually only show...

Страница 10: ...Please note that the steam on off function is completely independent of ECO mode So Eco Steam above might be highlighted but if the steam function is not switched on nothing happens and the steam boil...

Страница 11: ...ely be returned to the Home screen Note this only works if ECO mode is enabled via the Time Economy option page 20 is set to a value other than 0 1 3 2 4 Eco Steam mode only affects steam boiler recom...

Страница 12: ...time to warm up again In full eco mode both boilers the display switches to green when it enters ECO mode ECO setting is most useful when restricted to operate on the Steam boiler only Touch to highl...

Страница 13: ...you may decide to put the Vesuvius straight back into Eco mode Again if it helps think of this fairly quick procedure as 2 touches on the lower right corner of the display followed by 2 touches on th...

Страница 14: ...Touch to change time and day Touch to access service menu Does nothing touch to continue This actually shows E61 group lever operations The Vesuvius has an internal On Off timer with 2 on off times ea...

Страница 15: ...rofiles The profiling system is very easy to use and can achieve results as simple or complex as you care to program After you touch and hold a profile icon P1 for 5 seconds you will enter this screen...

Страница 16: ...ve to use them all Phase 1 Preinfusion times for the first low pressure phase You can choose to move straight to maximum pressure but the Vesuvius benefits from a preinfusion phase Note the preinfusio...

Страница 17: ...suvius uses pressure transducer commercial valve system and PID algorithm to control pump pressure Although not perfect it is better than a simple on off control which would be unable to manage rapidl...

Страница 18: ...24V 110W commercial unit Low water alarm Visual only Feet Metal height adjustable Steam and hot water wands Ball joint no burn Steam on left water on right Portafilters 2 1 single and 1 double spout...

Страница 19: ...at the point indicated for 10 seconds The options are shown in the order they appear Increase or decrease to improve visibility for particular display setting Set this to your preference can be normal...

Страница 20: ...fill level leave on Mid Low allows higher boiler water level High is less Both boilers heat at once or brew boiler priority if enabled Reduces max power consumption to 1500W approx Does nothing impor...

Страница 21: ...ore 1 Closing the mains water solenoid preventing flooding if a fault develops on a plumbed machine 2 Showing the red fill tank screen when the water level is low 3 The length of time the pump will ru...

Страница 22: ...repair may be very simple e g a leaking high pressure PTFE pipe joint and the dealer can talk you through quickly fixing it At other times it may be more serious and require the machine to be returned...

Страница 23: ...he sensitivity of the water sensor 1 loosen the 2 allen keys holding the sensor 3 unscrew the central screw in order to make better pictures we removed the side panel but you can do this also without...

Страница 24: ...uerra 9 80040 Cercola NA Ph Fax 39 0815552428 e mail info mevsrl net M V S r l vesuvius userguide10 June 2015 doc Page 24 of 24 Information Technology Solutions V ESUVIUS OWNERS MANUAL Appendix 2 Elec...